ELECTRICAL INSTALLATION AND USE 

Important:  The  electrical  installation  should  be  carried  out  by  qualified  personal  only, 
according to the regulations for electrical and mechanical safety in your country. 

 

Simply connect the projector to the mains and adjust the dimmer (7) on the back panel to the desired level. 
Use the 

“COLOR TEMP” knob to adjust the color temperature from warm white (WW) to cold white (CW). 

You can easily add optional filters (color, frost) by means of the magnetic filter holder (diameter : 7cm). 
 

MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All  screws  used  for  installing  the  device  and  any  of  its  parts  should  be  tightly  fastened  and  may  not  be 

corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a 

small problem is detected. 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically  to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumul

ation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 

 

SPECIFICATIONS 

This unit is radio-interference suppressed. This product meets the requirements of the current European and 
national guidelines. Conformity has been established and the relevant statements and documents have been 
deposited by the manufacturer. 

Mains Input: 

AC 180 - 240V, 50Hz  

Power consumption:

 

35 Watt  

Power connections:

 

Power cord, 1m with mains plug (CEE 7/7). 

Lamp:

 

LED, 30W COB CW + WW 

CRI: 

>

90

 

Beam Angle:

 

30° 

IP-Rating:

 

IP20 

Size:

 

see drawing 

Weight:

 

2,46 kg 

 

 

Содержание CAM-SPOT 30TW

Страница 1: ......

Страница 2: ......

Страница 3: ...ins power cord with standard mains plug CEE 7 7 on the back panel BEFORE USE Before you start using this unit please check if there s no transportation damage Should there be any do not use the device and consult your dealer first Important This device left our factory in perfect condition and well packaged It is absolutely necessary for the user to strictly follow the safety instructions and warn...

Страница 4: ...ged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to prevent electri...

Страница 5: ...cted certified installation materials should be used the installed device should be inspected regularly for safety Make sure the area below the installation place is free from unwanted persons during rigging de rigging and servicing Locate the fixture in a well ventilated spot far away from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls The de...

Страница 6: ...es it must be replaced The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected In order to protect the device from overheat the cooling fans if any and ventilation openings should be cleaned monthly The interior of the device should be cleaned annually using a vacuum cleaner or air jet The cleaning of internal and external optical l...

Страница 7: ...ENGLISH OPERATION MANUAL JB SYSTEMS 5 5 CAM SPOT 30TW The information might be modified without prior notice You can download the latest version of this user manual on our website www jb systems eu ...

Страница 8: ......

Отзывы: