27
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein T49 (0)7304-9617-0
3.5 Lamp control and lamp ignition
There are differnt modes for lamp ignition and lamp control available:
Lamp ignition configuration
is set in the fixtures personality configuration in Menu
LAMP MODE
possibility no.1: The lamp ignites as soon as the fixture powers up
(AUTO START)
possibility no 2: The lamp ignites as soon as the fixture powers up and a DMX value between
248 - 255 is send on channel no. 5
(AUTO OFF)
possibility no 3: The lamp ignites so soon as the fixture powers up and any DMX signal is
connected to the fixture.
(AUTO DMX)
Configuration of lamp control:
The lamp control configuration is independent to the lamp ignition mode.
The lamp control is based on DMX values. It is used to switch off the lamp by means of the
control console.
To enable the lamp control mode enter personality configuration of the fixture.
Activate menu
LAMP ON/OFF DMX
If the option
is selected in
menu, the lamp can only be controlled
OFF
LAMP ON/OFF DMX
(switched off) by DMX if possibility no. 2 is selected.
If the option
is selected in
the lamp will ignite like discribed
ON
LAMP ON/OFF DMX menu,
before and it can always be controlled (switched off) by DMX if there is a DMX value send
between 232-239 on channel no. 5 for more than 3 seconds.
Activate the standalone mode:
The standalone mode is activated in the menu: DMX/STANDALONE
independent if it was programmed manually or by a connected DMX board.
To enter menu DMX/STANDALONE press key MENU and afterwards key + three times.
You will find D
To confirm press Enter.
Select standalone-function by pressing key + and press ENTER one time to activate.
will be shown on the display
MX/STANDALONE displayed.
S-ALONE: 1 / 2
Deactivate the standalone mode:
To deactivate standalone mode press ENTER and key - one time.
The display will show:
Press key ENTER again and find
displayed
Escape by pressing key MENU
DMX MODE
DMX/STANDALONE