Varyscan* 4 1200 HMI
The bulb of the appliance does not
shine, but electronics are working, i.e.
motors are working
1. The bulb is defect, you have to
change it
2. The temperature switch of the
appliance is released. Plug out your
Varyscan* and after approximately 15
minutes plug it in again. Check now, if
both ventilators are working and if they
are clean. If one of the ventilators is
defect, have it exchanged by a specialist
or the producer. If the scanner turns off
again and again, please contact your
dealer.
DMX-input does not work
Control DIP-switch position
Adjustment of Mirror Stop
To adjust the mirror of your Varyscan* 1200 HMI, proceed as follows:
Adjust the initialisation mode at DIP- switch No.1 (DIP-switch position see page 7) and start
your Varyscan*. Now wait until the initialisation of the scan is ran through and all motors
stopped. Then loosen screw No.1 Now turn the
holder for the y-motor towards the stop up to a
distance of 0,5 mm. Tighten screw No.1 now.
During tightening the screw pay attention to the
correct adjustment of the motor brake (see
sketch below). Loosen screw No.2 and turn the
y-motor towards the holder for the y-motor and
adjust hereby a distance of 0,5 mm between
the stop and the holder for the y-motor.
Adjustment of the motor brake
The motor brake is similar at each of the stepping-motor of the scan. There are three special
parts (part no. 2,3 and 4) which must be installed in the following
succession:
Part no. 1.
motor
Part no. 2.
Tellerfedern
Part no. 3.
Stahllaserteil
Part no. 4.
Kunststoffscheibe
Part no. 5.
zu montierendes Teil
Содержание Varyscan 4 1200 HMI
Страница 2: ...2 Varyscan 4 1200 HMI Bedienungsanleitung deutsch Seite 05 38...
Страница 3: ...3 Varyscan 4 1200 HMI Operating Instructions english Page 39 70...
Страница 4: ...4 Varyscan 4 1200 HMI Bedienungsanleitung...
Страница 8: ...8 Varyscan 4 1200 HMI R ckansicht und Lage der Bedienelemente...
Страница 14: ...14 Varyscan 4 1200 HMI 2 7 3 13 4 19 5 25 6 31 7 37 Varyscan Nr DMX Adresse Schaltereinstellung 8 43 9 49...
Страница 30: ...30 Varyscan 4 1200 HMI Belegung der Steckerleisten und Jumper...
Страница 35: ...35 Varyscan 4 1200 HMI Best ckungsplan Platine Varyscan 4 1200 HMI...
Страница 36: ...36 Varyscan 4 1200 HMI...
Страница 37: ...37 Varyscan 4 1200 HMI Operating Instructions...
Страница 41: ...41 Varyscan 4 1200 HMI...
Страница 47: ...47 Varyscan 4 1200 HMI 2 7 3 13 4 19 5 25 6 31 7 37 Varyscan No DMX address DIP switch position 8 43 9 49...
Страница 64: ...64 Varyscan 4 1200 HMI Occupation of connectors and Jumper...
Страница 69: ...69 Varyscan 4 1200 HMI Plan of electronic parts for electronic board of Varyscan 4 1200 HMI...