Charging
Other charging methods are possible by using additional adapters for different canister
types, including side can piercing
See www.jbind.com for canister adapter kit information
Inverted Charging:
1. Connect the charging hose to the scale side port
2. Connect the other end of the charging hose (with the charging valve closed)
to the system
3. Attach the Secure Seal adapter fitting to the refrigerant canister
4. Invert the can and connect the Secure Seal fitting to the fitting on the scale platter
5. Turn on the scale and scale will display combined weight of cylinder and gas
6. Short press “TARE” button to zero scale
7. Charge the system by throttling the charging valve and monitoring the scale weight
8. Once the proper weight is transferred from the canister to the system, close the
charging valve and remove the charging hose from the system
Inverted
Charging