background image

 

- 12 - 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 13                                                                                           

Fig. 14

 

 
 

 

 

Manual disengagement 

The opener is equipped with a manual release cord to disengage the shuttle and move the door by hand (Fig 15). Pull   

the handle downwards to disengage the shuttle, then lift the door by hand (do not try to lift the door with the manual 

release  cord)  To  re-engage  the  shuttle  simply  flick  the  manual  release  cord  backwards  so  that  the  attaching  arm  is 

facing towards the opener head unit then run opener in automatic mode or move door by hand until the trolley engages 

in the chain shuttle (spring loaded)   

In some situations where no other access to the garage is possible, it is recommended that an external disengagement 

device or 

coffin lock

 should be fitted (Fig 16). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig.16 

Fig.15 

Содержание 600N

Страница 1: ...re installation and use The installation of your new door opener should be carried out by a technically qualified person Attempting to install or repair the door opener without suitable technical qual...

Страница 2: ...k assembly optional 6 Battery backup assembly optional 7 Basic function settings 7 Special functions optional parts introduction and application 11 Manual disengagement 12 Maintenance 13 Final notes 1...

Страница 3: ...hout observing all the applicable safety standards will be responsible for any damage injury expense or claim as a result of failure to install the system correctly and in accordance with the relevant...

Страница 4: ...a warning sign advising to keep children away from a moving garage door having a height of at least 60 mm Periodically check that this warning is still in place This garage door opener is supplied wi...

Страница 5: ...ng function so the garage door can still be locked manually in the event of a power outage 12 1200Nm lifting force 13 Safety reverse function The door will reverse to the fully open position when enco...

Страница 6: ...nces Important note It is thoroughly recommended that the installation of a garage door opener be carried out by a trained Technician DIY is an option but proceed at your own risk Installation 1 Read...

Страница 7: ...r falling and may cause serious damage and or personal injury Installation steel track 1 Fix the wall bracket B to the wall 2cm 15cm above the torsion shaft or spring and central to the door 2 Fix the...

Страница 8: ...hexagon bolts and nuts supplied before connecting adjust to a suitable length 10 Release the clutch try to open and close the door by hand Make sure there is no contact between door panel and track 11...

Страница 9: ...illuminated Fig A Press a preferred button on transmitter once the LED dot will extinguish press the same button on the transmitter again The transmitter is now coded into the receiver Repeat the abov...

Страница 10: ...he position by momentarily pressing the UP and DOWN buttons to determine the final close limit position then press SET If the opener stops and displays H or C this indicates there s no hall signal or...

Страница 11: ...1 minute The auto close function will be turned off when the LED displays 0 Press SET button to confirm the opener returns to standby mode The auto close function is only be available when the door i...

Страница 12: ...rns to standby mode When the lock door function is on and the door is fully closed the opener will lock the door automatically The door can only be opened by a transmitter after unlocking by the lock...

Страница 13: ...for this function and provide 24v 35v flashing light voltage Connect the flashing light with DC 24v 28v current 100mA When using AC 220V power flashing lights please match an adapter and wiring as re...

Страница 14: ...th the manual release cord To re engage the shuttle simply flick the manual release cord backwards so that the attaching arm is facing towards the opener head unit then run opener in automatic mode or...

Страница 15: ...ly to be used by technical persons who are qualified to carry out the installation It is important for the installer to show their clients correct operation of the opener including the procedure for m...

Страница 16: ...qm 18 0 sqm Rated lifting force 60 kgs 80 kgs 100 kgs 120 kgs Rail Steel Aluminum Steel Aluminum Steel Aluminum Steel Aluminum Drive Chain Belt Chain Belt Chain Belt Chain Belt Motor 24V 100W 24V 120W...

Страница 17: ...Safety reverse function Obstruction or door maintenance required 1 Check for any obstructions 2 Call a Professional Technician for maintenance Transmitter doesn t work 1 Flat battery 2 Antenna is loo...

Страница 18: ...ees that they may be charged a call out fee plus any parts required to complete the repair Liability Australia only Under no circumstances shall the Seller be liable for consequential incidental or sp...

Страница 19: ..._____ _______ Contact Details ______________________________________________________________________________________________ Notes______________________________________________________________________...