APRIL 2017
page 3
www.jayline.co.nz
Congratulations on the purchase of your Jayline wood fi re.
Please read this installation and operation manual carefully.
The installation of this fi re must comply with the Installation Standard
AS/NZS 2918:2001 as well as any additional local requirements.
Please ensure you have all relevant permits prior to installation.
Keep this booklet as a reference guide.
INSTALLATION OF YOUR JAYLINE WOOD FIRE
Jayline recommends you use a suitably qualifi ed installation technician to install your fi re. Your dealer
or heating specialist will be able to help with recommendations as well as advise on permits/consents
required for the installation in your area.
Please follow carefully all dimensions and recommendations provided on the individual specifi cation
sheet for your model of heater as these dimensions comply with the required New Zealand standard
(AS/NZS 2918:2001).
As safety and emissions performance can be aff ected by altering the appliance, no modifi cations are
allowed without the written permission from the manufacturer.
INSTALLATION
1. Unpack the heater and check that there is no damage.
2. Ascertain the position of the roof penetration for the fl ue system.
A correctly installed fl ue system will normally prevent down draught problems during windy
weather and eliminate smoke spillage problems due to lack of draught.
3. Ascertain suitable position for appliance and size of fl oor protector and check the ceiling to ensure
that no major structural members will be aff ected by the path of the fl ue.
4. Check that the sub-structure is capable of carrying the heater (i.e. weight consideration on the fl oor).
5. Check measurements of the heater to combustibles or shield.
6. Locate the heater in the required position (also see
‘Fitting Seismic Restraint’
after installation
instruction #10).
7. Using a plumb line fastened to the ceiling, mark the centre of the fl ue penetration position and cut
the ceiling hole to the required size and frame out.
8. Install the fl ue system (see fl ue installation instructions supplied with fl ue system).
Remember:
• The fl ue system should rise vertically from the appliance with as few off sets as possible. Off sets
should be limited as each change in direction creates a resistance to airfl ow and makes fl ue
cleaning diffi cult.
• The fl ue system must be well sealed with a minimum of 3 fi xings at each joint.
• The fl ue pipe penetrating the chimney must continue to the minimum length of 4.6m from the top
of the fl oor protector to the cowl.