SECTION 8 – PLUMBING SYSTEMS
JAYCO CLASS A MOTOR HOMES
8-12
When you are finished draining the fresh water system, reverse these steps and
dump the grey and black water holding tanks at an appropriate facility or according
to local public codes.
U
TILITY
C
ENTER
The following information defines the function of the utility center settings
indicated on the utility center label:
City Fixtures
- This setting allows you to access water at all faucets using city
water.
City Tank Fill
- This setting allows you to fill your fresh water tank using city
water.
Country Fill
- This setting allows you to fill your fresh water tank (using the 12-volt
water pump) when you do not have access to city water.
Normal
- If the RV is not connected to city water, this setting allows you to pump
water from the fresh water tank to all faucets using the 12-volt water pump.
Sanitize/Winterize Lines
– This setting allows you to sanitize or winterize your
fresh water system.
Sanitize Tank
– This setting allows you to sanitize the fresh water tank.
The city water connection inlet is located in the utility compartment. We
recommend that you use a non-toxic drinking water hose dedicated only to
supplying the motor home with fresh water (to reduce the chance of
contamination, prevent the non-toxic drinking water hose from coming into contact
with the ground). Install the city water connection inlet cap when the fresh water
connection is not being used. Do not remove the following label from your motor
home
:
Fig. 8.5 Potable water only label
The fresh water connection should be unplugged (i.e., the non-toxic drinking
water hose disconnected) when the motor home is unattended for any
amount of time. If something would happen to the water system, this may
help limit water damage to a smaller area.
C
ITY
W
ATER
F
ILL
Use this setting if you are at a campground or other facility where the motor home
can be hooked up to an external water source.
1. If needed, sanitize the water system prior to travel.
2. Move the “water heater bypass valve” to the NORMAL position.
3. Remove the city water connection inlet cap and attach a non-toxic drinking
water hose to the city water connection inlet.
4. Place the utility center valves in the “City Fixtures” position.
5. Turn ON the water at the external water source.
Содержание 2015 PRECEPT
Страница 1: ...2016 ALANTE 0253835 2016 PRINTED ON RECYCLED PAPER Generations of family fun CLASS A MOTORHOMES...
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS ALANTE CLASS A MOTOR HOMES VI THIS PAGE IS INTENTIONALLY BLANK...
Страница 38: ...SECTION 3 PRE TRAVEL INFORMATION JAYCO CLASS A MOTOR HOMES 3 6 Fig 3 5 Towing and braking label...
Страница 54: ...SECTION 5 SLIDEOUT SYSTEMS JAYCO CLASS A MOTOR HOMES 5 4 THIS PAGE IS INTENTIONALLY BLANK...
Страница 76: ...SECTION 7 FUEL PROPANE SYSTEM JAYCO CLASS A MOTOR HOMES 7 10 THIS PAGE IS INTENTIONALLY BLANK...
Страница 96: ...SECTION 8 PLUMBING SYSTEMS JAYCO CLASS A MOTOR HOMES 8 20 THIS PAGE IS INTENTIONALLY BLANK...
Страница 104: ...SECTION 10 APPLIANCES JAYCO CLASS A MOTOR HOMES 10 6 THIS PAGE IS INTENTIONALLY BLANK...
Страница 112: ...SECTION 12 INTERIOR JAYCO CLASS A MOTOR HOMES 12 6 THIS PAGE IS INTENTIONALLY BLANK...