SECTION 8
PLUMBING SYSTEMS
is full, shut OFF the water pump and remove
the non-toxic drinking water hose.
W
ATER
P
RESSURE
R
EGULATOR
(C
USTOMER
S
UPPLIED
)
Excessive pressure from water supply
systems may be encountered in some parks,
especially in mountain regions. Water
pressure regulators are available to protect
your system against such high pressure. A
regulator of this type is recommended to
prevent damage to the plumbing system or
components. Water pressure regulators
(customer supplied) are available from your
Dealer to protect the RV plumbing system
against such high pressure.
12-V
OLT
W
ATER
P
UMP
&
S
WITCH
(I
F
S
O
E
QUIPPED
)
Once activated, the water pump (also known
as the on-demand pump) will self-prime, and
provide water. The water pump continues to
run until approximately 45 lbs. of pressure is
achieved and shut off. The water pump will
automatically re-start when pressure drops.
Some cycling may occur, depending on the
volume of water being released. The water
pump is engineered by the OEM with a check
valve to prevent water from back flowing into
the fresh water supply tank
The water pump switch should be in the
OFF position when the RV is left
unattended for any amount of time. If
something would happen to the water
system, this may help limit water damage
to a smaller area.
Dry camping
When you want to use water in your RV and
the RV is not hooked up to city water, you will
need sufficient 12-volt DC power to run the
water pump.
Fig. 8.3 Water pump strainer
W
ATER
H
EATER
The water heater is designed to heat water
quickly and efficiently. The water heater
manufacturer has preset the sensing limit to
maintain the water temperature when the
water heater is activated. Hydrogen gas in the
water lines may result if you have not used
the water heater for two weeks or more. To
reduce the risk of injury under these
conditions, open the hot water faucet for
several minutes at the kitchen sink before you
use any electrical appliance connected to the
hot water system. If hydrogen is present, you
probably will hear an unusual sound such as
air escaping through the pipe as the water
begins to flow. Hydrogen gas may be present
even after water has been drained from the
tank. Open the sink faucet at the sink and
allow system to vent for five to ten minutes (or
as needed).
Not using a water pressure regulator when
using city water may cause the o-rings to
fail. To prevent damage to the plumbing
system or components when using the city
water connection, a water pressure
regulator rated for 40 lbs. is recommended.
Do not replace any component part with an
accessory part that is not authorized by the
water heater manufacturer, such as an
“add-on” electric heating element. Such
items are not approved to be installed and
could create an unsafe condition and will
void all warranties.
53
Содержание 2012 OCTANE SUPER LITE
Страница 1: ...OWNER S MANUAL 2012 P N 0187099 2012 SPORT UTILITY TRAVEL TRAILERS OCTANE SUPER LITE OCTANE ZX...
Страница 26: ...SECTION 2 OCCUPANT SAFETY 22 THIS PAGE IS INTENTIONALLY BLANK...
Страница 34: ...SECTION 3 PRE TRAVEL INFORMATION 30 THIS PAGE IS INTENTIONALLY BLANK...
Страница 44: ...SECTION 5 RV TIRES 40 THIS PAGE IS INTENTIONALLY BLANK...
Страница 54: ...SECTION 7 FUEL SYSTEM 50 THIS PAGE IS INTENTIONALLY BLANK...
Страница 72: ...SECTION 9 PROPANE SYSTEM 68 THIS PAGE IS INTENTIONALLY BLANK...
Страница 96: ...SECTION 13 SPECIFICATIONS GLOSSARY OEM WHEEL LUG TORQUE CHART 92...