3.  CLASSIFICATION AND COMPLIANCE

1) FT-500(R/L) is classified as ;

- Class 1 type-BF against electric shock

- Ordinary equipment without protection against ingress of water 

- Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of 

IEC 60601-1(Safety of Medical Electrical Equipment)

2) FT-500(R/L) are complied with Class A for Noise-Emission, Level B for Noise-immunity, by 

standard of IEC 60601-1-2(Electromagnetic Compatibility Requirements).

3) This blood pressure meter complies with the EN 1060-1 : 1995 Non-invasive

Sphygmomanometers general requirements as well as EN 1060-3 : 1997 supplementary

requirements for electro-mechanical blood pressure measuring systems.

4. SAFETY PRECAUTIONS

FT-500(R/L) is designed and manufactured with consideration given to the safety of the

operator and subject and also to the reliability of the unit.

The following precautions must be observed for additional safety ;

1) The unit must be operated only by, or under supervision of, a qualified person by JAWON

or his distributor.

2) FT series are specified as Class 1 type BF unit under the standard of IEC 60601-1(Safety

of Medical Electrical Equipment).

Therefore, patients must not touch or handle inner side of the system at any time.

3) Do not modify the unit. If any modification is desired, ask JAWON or its authorized  dealer

for service.

4) The unit has been factory-adjusted for optimum performance.

Do not attempt to adjust any pre-controls or switches except those specified in this

manual for operation.

5) If you have experienced any trouble with the unit, switch it off immediately, and contact

JAWON or its authorized dealer for assistance.

6) If you plan to connect any device of other manufacturers electrically or mechanically to

this unit, contact JAWON or its authorized dealer for instructions before doing so.

When you connect computer or other system to the unit(RS-232C), the attached systems

should be certified by IEC 950 or equivalent standards for data processing equipment.

Configurations shall comply with the system standard IEC60601-1-1. 

Everybody who connects additional equipment to the signal input part or signal output part

configures a medical system standard IEC 60601-1-1.

If in doubt, consult the A/S department of local distributor.

Содержание FT-500R

Страница 1: ......

Страница 2: ...R 9 3 REAR PART 10 4 ACCESSORIES 12 5 OPTIONS 12 1 CONNECTING POWER CABLE AC INPUT 13 2 ASSEMBLING OF ARM REST 13 3 LOADING THE PRINT PAPER 14 4 CONNECTING PORTS RS 232C 14 5 SETTING TIME AND DATE 15...

Страница 3: ...monitor armed with the belt type cuff that facilitates the test time quicker and provides the results more reliable 2 WORD DEFINITIONS To ensure safe operation and long term performance stability it...

Страница 4: ...tor 2 FT series are specified as Class 1 type BF unit under the standard of IEC 60601 1 Safety of Medical Electrical Equipment Therefore patients must not touch or handle inner side of the system at a...

Страница 5: ...ailure of user to maintain the unit relieves the manufacturer or his agent of the system s non compliance with specifications or responsibility for any damage or injury This manual is made for informa...

Страница 6: ...pectively Identifies equipotential ground located next to ground stud on rear panel IEC 417 5021 Identifies the point where the safety ground of the system is fastened to the chassis Do not open This...

Страница 7: ...d due to high pressurizing or irregular operation is done press this button then the cuff will be exhausted rapidly PRINTER COVER It protects the printer AUTOMATIC CUTTER Printer paper let out slot Pr...

Страница 8: ...tached to FT 750AF R L model ID card can be issued either by the machine manager or by the manufacturer of the model The card can store ID number and measured results The card stores two previous meas...

Страница 9: ...all memorized data would be deleted When you set the date and time use as a key which increases the number FEED button Use this button for setting the paper When you set the date and time use as a ke...

Страница 10: ...en the main body and a computer or other equipment with cable RS 232C to transfer the data collected or measured second for connecting between the main body and the coin slot with RS 232C calble to tr...

Страница 11: ...INFORMATION BOARD FIXER VOLUME ANNOUNCE ON OFF CARD ON OFF SOUND ON OFF SENSOR ON OFF PRINT ON OFF REAR PART EARTH POTENTIAL EQUALIZATION TERMINAL CAL AC INPUT POWER FUSE PORT RS 232C...

Страница 12: ...4 ACCESSORIES Manual Poster Guide Arm rest 5 OPTIONS Cart Chair Card reader Card writing device Cards Printer paper Printer Human sensor Earth Power Fuse...

Страница 13: ...n the rear and turn the POWER ON OFF switch O I on the lower part of the rear See the picture 2 ASSEMBLING OF ARM REST The arm rest is divided into two parts the first one is built in the unit as it i...

Страница 14: ...C To transmit the data with connecting a computer or other external options to the unit Connect the RS 232C cable both to port of the unit and to the computer jack or other external options See the pi...

Страница 15: ...says its counts that have been measured since keeping button ON Press SET button one more First 2 figures will blink To set the current hour press PRINT button to make the number goes up or press FEED...

Страница 16: ...legs crossed When you fold your sleeves up please make sure not to press your arm Put your arm deeply in order to fit to the arm rest If it is not easy to check your pulse with the stethoscope the me...

Страница 17: ...er When the card is inserted a voice message comes out to press the start button Put your right or left arm into the cuff deeply For FT 500R measure with right arm for FT 500L measure with left arm No...

Страница 18: ...her than actual value and vice versa Note When the measurement is started the voice message is announced as Starting measurement don t move or speak please When you feel painful and want to stop the m...

Страница 19: ...E is SYSTOLIC 000 DIASTOLIC 000 PULSE 000 Note When the PRINT ON OFF switch on the rear is set as OFF the result will not be printed even if the measurement is completed Pull your arm out Note For the...

Страница 20: ...leaks message appears on the printer as ERROR CUFF When the message is repeated call for maintenance service When a testee moves or speaks while in testing message appears on the printer as ERROR MEA...

Страница 21: ...ower off The cuff cover will be strained Detach the cuff cover from the magic tape The location of the magic tape is as the picture Pull the upper part of the cover down direction and then pull out th...

Страница 22: ...do not mount it close to the gas pipe water pipe lightening rod and connection of telephone When you take out the plug grasp the plug exactly Keep the unit dry and do not wet it Never immerse the main...

Страница 23: ...ery 2 years Do not put heavy things on the unit Check the unit conditions occasionally Do not use the unit under the condition of shock or vibration Do not install and shock with chemicals or gas When...

Страница 24: ...l assist your appropriately qualified technical personnel to repair those parts of unit which are designated by JAWON as repairable How to contact JAWON MEDICAL CO LTD Write us at JAWON MEDICAL CO LTD...

Страница 25: ...C AC120V 60Hz US Power consumption 50VA Ambience for operation Temperature 10 40 Humidity Less than 85 non condensing Ambience for storage Temperature 5 50 Humidity Less than 85 non condensing Data tr...

Страница 26: ...NO Note When you receive this warranty make sure that the name of the dealer and the month day and year of purchase are all completed This warranty will not be reissued please keep it in a safe place...

Страница 27: ......

Страница 28: ...www jawon co kr...

Отзывы: