7.3
Elevator cleaning
The blades of the elevator must be cleaned regularly
in order to prevent excessive wear.
Procedure:
1.
Loosen the two guards of the elevator, using
the supplied door key and remove it from the
machine.
2.
Spray the blades of the elevator (A) and the
elevator chain with compressed air.
3.
Attach the two guards of the elevator, using
the supplied key, on the machine.
7.4
Test safety circuit
Procedure:
1.
Start the machine.
2.
Press the emergency stop button. The machine is now disabled.
3.
Pull the Emergency Stop button. The machine remains off.
4.
Press the reset button emergency stop circuit. All possibly connected conveyors start moving.
5.
Start the machine
The machine must not be used when going through the above process, the machine responds differently than
described above. Warn directly Javo BV.
7.5
Fault list
Problem
Possible cause
Action / Solution
Motor fault
mains voltage deviates more than
10% of the rated motor voltage
Provide the correct voltage
Too high cooling air temperature Provide cool air
Poor cable connection
check the cable connection and repair if necessary
Blown fuse
Replace fuse
Too little cooling air caused by a
clogged cooling air passage
Ensure proper inlet and outlet of the cooling air
The motor hums and takes
too much power
Defect winding
Repair or replace the motor winding
Loose wire
Lock wire
Fuses are blown
Short circuit in wiring or motor
Rectify the short circuit
Motor short circuit to housing or
has a short in the windings
Turn to a repair shop to fix the short circuit
Motor is connected incorrectly
Connect the motor correct
Minimum substrate in the
trays
Too little substrate in the bin
Fill the bin with substrate
Elevator provides little substrate
Set the substrate conveyor faster
A