Sigma as Rover
HPT404BT Configuration
8
www.javad.com
HPT404BT Configuration
To configure the HPT404BT, perform the following:
1. Attach the UHF antenna to BNC antenna connector.
2. Connect the modem to PC using serial (RS232) or USB port. If the USB connection will be used,
ensure the special USB driver is downloaded from JAVAD GNSS’s website and installed (http://
javad.com/downloads/javadgnss/drivers/usb/jgnss_usbser.zip).
Note:
New virtual COM port will appear after connecting HPT404BT to PC. This port should be selected to
establish the USB connection with HPT404BT.
3. Power the modem.
4. Ensure you have the latest version of ModemVU installed on your PC. The latest version is avail-
able on http://www.javad.com/jgnss/products/software/modemvu.html
5. Start ModemVU
6. Select
HPT404BT
in the
Options
window and click
Ok
Figure 6. ModemVU. Options
7. Connect to virtual COM port, if the USB connection is used:
8. Configure the parameters in the
Radio Link
tab. Please ensure all parameters are identical to base
parameters: frequency, modulation type, link rate, link space, Forward Error Correction and
Scrambling. Set the corresponding Protocol.