background image

Sigma as Rover

Sigma Configuration

7

www.javad.com     

 

                                                                                                                                     

    

  

     

  

12.  Click Parameters on the left and then select 

pd

 for 

Position Computation Mode

 and click 

Apply

:

Figure 5. NetView. Positioning tab

Now HPT404BT should be configured. Do not turn off the SIGMA receiver.

Содержание SIGMA

Страница 1: ...ontained herein may not be used accessed copied stored displayed sold modified published or distributed or otherwise reproduced without express written consent from JAVAD GNSS SIGMA as Rover with HPT404BT connected through Bluetooth Configuration Example Version 1 0 Last Revised December 21 2011 ...

Страница 2: ...www javad com ...

Страница 3: ...e receiver to PC using serial RS232 or USB port If the USB connection will be used ensure the special USB driver is downloaded from JAVAD GNSS s website and installed http javad com downloads javadgnss drivers usb jgnss_usbio zip 4 Power SIGMA receiver 5 Ensure you have the latest version of NetView installed on your PC The latest version is available on http www javad com jgnss products software ...

Страница 4: ...ck the satellites are tracked Click on the receiver s name on the left On the right the informa tion about tracked satellites will be displayed Figure 2 Satellites 8 Click GREIS Commands tab on the left and then click Capture on the right Figure 3 on page 5 ...

Страница 5: ...click Send Than copy or enter the SIGMA Bluetooth Mac Address i e the value of the parameter addr Figure 3 GREIS Commands 1 10 Enter the command set dev ser e imode rtcm3 and click Send Note The correction type should be the same as base transmits In the example above the rtcm3 is selected ...

Страница 6: ...Sigma as Rover Sigma Configuration 6 www javad com 11 After the receivers reply RE002 click the Release button Figure 4 Figure 4 GREIS Commands 2 ...

Страница 7: ...figuration 7 www javad com 12 Click Parameters on the left and then select pd for Position Computation Mode and click Apply Figure 5 NetView Positioning tab Now HPT404BT should be configured Do not turn off the SIGMA receiver ...

Страница 8: ...cting HPT404BT to PC This port should be selected to establish the USB connection with HPT404BT 3 Power the modem 4 Ensure you have the latest version of ModemVU installed on your PC The latest version is avail able on http www javad com jgnss products software modemvu html 5 Start ModemVU 6 Select HPT404BT in the Options window and click Ok Figure 6 Figure 6 ModemVU Options 7 Connect to virtual C...

Страница 9: ... javad com 9 In the BT tab set the BT to off and click Apply Figure 7 BT tab 10 Enter the SIGMA s MAC Address to the Destination Address field Set Mode to Master and then BT to ON Figure 8 Settings for BT tab 11 Click Apply to save the settings ...

Страница 10: ...Sigma as Rover HPT404BT Configuration 10 www javad com Connect to the SIGMA via NetView If all parameters were set correctly SIGMA will receive the fixed solution Figure 9 NetView ...

Страница 11: ...Sigma as Rover HPT404BT Configuration 11 www javad com ...

Страница 12: ...900 Rock Avenue San Jose CA 95131 USA Phone 1 408 770 1770 Fax 1 408 770 1799 www javad com Copyright JAVAD GNSS Inc 2011 All rights reserved No unauthorized duplication ...

Отзывы: