JT6200M Outdoor CPE  

 

User Manual V1.0 

 

 

 

 

 

Jaton Technology Limited. C

ONFIDENTIAL 

 

This document and the information contained in it is confidential information of Jaton Technology Limited (Jaton), and 

shall not be used, or publish, or disclosed, or disseminated outside of Jaton in whole or in part without Jaton

’s consent. 

This document contains trade secrets of Jaton. Reverse engineering of any or all of the information in document is 

prohibited. The copyright notice does not imply publication of this document 

© 

C

OPYRIGHT 2007-

2016, Jaton Technology Limited. 

CONFIDENTIAL INFORMATION 

Information contained herein is proprietary to Jaton for whose benefit 

Confidentiality shall be maintained 

Содержание JT6200M

Страница 1: ...isseminated outside of Jaton in whole or in part without Jaton s consent This document contains trade secrets of Jaton Reverse engineering of any or all of the information in document is prohibited The copyright notice does not imply publication of this document COPYRIGHT 2007 2016 Jaton Technology Limited CONFIDENTIAL INFORMATION Information contained herein is proprietary to Jaton for whose bene...

Страница 2: ... that are supplied in your LTE CPE Unit Installation Package Please take time to unpack the package and check its contents against this list LED Indicators Type LED Function Description Router SYS Power indicator Orange Color Device is powered on Blinking green Wireless access not ready Green Color Network is available NET WAN port status Blinking green The data is in transmission SIG RF signal in...

Страница 3: ...r on the device the CPE must use a 48V DC power supply adapter The power adapters can operate in 90 250V AC range and therefore can be used in different country An Ethernet cable is required to connect the WAN port of IDU with the POE LAN port of ODU By the way the ODU don t support the hot plugging Once the device is powered up the user should wait for about 1 minute before the device becomes ope...

Страница 4: ...ly in horizon direction to find the best signal direction then fixed it with the anchor ear The CPE radio signal strength level can be observed from the RF LEDs mounted on the lower panel as shown below The more LEDs on the better the signal strength Installing Outdoor Unit ODU Mounting Bracket ...

Страница 5: ...allation grounding or lightning protection The Grounding screw is located on the lower part at the back of the unit see Figure below Use 10 AWG cable for grounding Connect one of a grounding cable to the grounding screw and firmly tighten the grounding screw Connect the opposite end of the grounding cable to a good ground earth connection Connecting to Your Device JT4200M supports several manageme...

Страница 6: ...will appear Note that the default user password is user123 Device Status Once the user log in the following window device status window will be prompted for viewing It contains both the wireless link information networking and device information configured for the device For wireless info gives quite detailed information about the radio connection and user can use it to determine the receiving sig...

Страница 7: ...ce Reset In case the user forgets the login password a reset button is designed between WAN port and DC port The user can pull down the reset button for 10 seconds with power on then a system reset will be performed and the unit will be rebooted The user can then be allowed to use the original default login password to gain access to the unit WEB GUI again After factory reset the device may need t...

Страница 8: ...e unplug the Ethernet cable from PC and wait for about 5 seconds then connect it again If the problem persists please contact the operator or distributor for further diagnose My CPE networking is not working properly You may want to check if the LTE connection is up and running properly You can do this by login the WEB GUI and check the Interface Info page You may want to perform a factory reset a...