Connecting external control voltage
NOTE
Mark up any junction boxes with warnings for
external voltage.
When connecting external control voltage, remove the
bridges from terminal block X5 (see image).
L
EK
L
0
4.
2.
3.
1.
Connect external control voltage (230V~ 50Hz) to ter-
minal block X5:L, X5:N and X5:PE (as illustrated).
F2120
Externt
AA2:X5
N
L
N
L
External
JÄSPI Inverter Nordic
Communication
Software version
In order for JÄSPI Inverter Nordic to be able to commu-
nicate with indoor module / control module the software
version must be according to the table.
Software version
Indoor module /
Control module
v7865
Jäspi Tehowatti AIR
v7839R2
Jäspi MCU 40
Disconnect the connections in JÄSPI Inverter Nordic
When connecting communication to an indoor mod-
ule/control module, you need to disconnect the connect-
ors in JÄSPI Inverter Nordic.
PRESS
1
PULL
LEK
2
3
PRESS
1
PULL
LEK
2
3
PRESS
1
PULL
LEK
2
3
PRESS
1
PULL
LEK
2
3
Pull up
Push down
1
2
3
JÄSPI Inverter Nordic
Chapter 5 |
Electrical connections
24
Содержание Inverter Nordic 8