background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 11 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2014 Jason International.

OPERATING INSTRUCTION, FEATURES, AND CONTROLS

INTRODUCTION

This manual contains all of the information needed for the 
proper installation and operation of your Jason MicroSilk

®

AirMasseur

®

 bath. The bath has been designed to give you 

years  of  relaxing  trouble-free  service,  provided  the  unit  is 
maintained and operated in accordance with these instructions. 

Thoroughly clean and disinfect the unit as described in 
the 

CLEANING

 section of the 

USER MAINTENANCE 

INSTRUCTIONS

 section of this owner’s manual before its first 

use and periodically thereafter. 

CAUTION: 

Keep hair, towels, and clothing away from the 

suction fitting whenever the equipment is On. Never operate 
the equipment with the suction cover off, as doing so voids 
the manufacturer’s warranty. It is a safety cover designed to 
eliminate the potential of hair and body entrapment. 

All Jason MicroSilk

®

-AirMasseur

®

 baths are pre-plumbed at 

the factory. 

WARNING: Before operating refer to the instructions at 
the end of this owner’s manual pertaining to the risk of 
fire, electric shock, or injury to persons.

FEATURES AND CONTROLS

STANDARD AND PREMIER EDITION MICROSILK

®

-AIRMASSEUR

®

The Jason Standard Edition MicroSilk

®

-AirMasseur

®

 bath 

provides both a Microbubble generator unit and an air bath 
system. The air bath system includes a variable-speed, 
1-HP air blower with heater and three (3) massage modes: 
Continuous, Wave, or Pulse; an electronic control; and a 
20-minute timer.

The Jason Premier Edition MicroSilk

®

-AirMasseur

®

 bath 

provides all the features of the Standard Edition with the 
included benefits of a LED Chromatherapy Mood Light, and 
an Ozone Sanitation system. 

Standard/Premier Touchpad

One main control touchpad mounted on the bath deck features 
several icons used by the bather to control the MicroSilk unit, 
blower, and LED mood light. A built-in timer shuts the pump 
off 20 minutes after being activated.

Standard / Premier Edition Automatic Purge

Fifteen (15) minutes after the control has shut off, the 
blower will start again for a two-minute purge cycle that 
dries the air channel. Note that the blower light will flash 
during the 15-minute pause before the purge cycle begins. 
Once the purge cycle begins, all indicators will light and 
the keypad operation will be disabled for two (2) minutes.

SIGNATURE EDITION MICROSILK

®

-AIRMASSEUR

®

The Jason Signature Edition MicroSilk

®

-AirMasseur

®

 bath 

includes both a Microbubble generator unit and an air bath 
system. The air bath system includes a variable-speed, 
1-HP air blower with heater and three (3) massage modes: 
Continuous, Wave, or Pulse. The system also includes 
Chromatherapy mood lights, Automatic Ozone System that will 
be operated any time the MicroSilk

®

 unit is powered; a digital 

control with LCD display window; low water and temperature 
sensors; and a 20-minute timer.

Signature Touchpad

A main control touchpad mounted on the bath deck features an 
LCD readout which alternately indicates the water temperature 
(+/- 5°F) and time remaining. The Signature Edition touchpad 
allows the bather to control the MicroSilk

®

 unit, blower, and 

LED mood light. A built-in timer shuts off the pump 20 minutes 
after being activated. 

Signature Remote Control

In addition to the main control touchpad installed on the bath 
deck, a floating, waterproof Universal Remote Control is 
provided with all Signature Edition MicroSilk

®

-AirMasseur

®

 

baths. This remote control provides the same control functions 
as the bath’s main control console, plus the bather may 
remotely operate a TV, DVD, VCR, CD, etc. Refer to the 
Instruction Manual provided with the remote control for detailed 
instructions.

Signature Edition Automatic Purge

Twenty (20) minutes after the control has shut off, the blower 
will start again for a two-minute purge cycle that dries the air 
channel. Note that the LCD display will read “PURGE” and 
begin to countdown the 10 or 20 minute pause before the purge 
cycle begins. The readout will display “PURGE ON” during 
the purge cycle. Any time during the pause before the purge 
cycle begins, pressing and holding the Blower Speeds icon 
will reduce the pause from 20 minutes to 10 minutes. During 
the two-minute purge, pressing the “Blower On/Off” icon will 
stop the purge. 

Signature Edition Daily Purge

The daily purge can be activated through the customized 
settings of the Signature Edition touchpad. When activated, the 
daily purge will start the blower for two-minutes at the same 
time every day to dry the air channel. See “Operating  The 
Signature Edition MicroSilk

®

-AirMasseur

®

 Touchpad” section 

for details on activating this setting.

Содержание forma Designer MicroSilk AirMasseur

Страница 1: ...responsible for ensuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been...

Страница 2: ...minimum ventilation opening of 2 x 4 5 x 10 cm for the blower is required and should be designed to draw in indoor ambient air at a minimum of 72 F 22 C 4 Install the drain and overflow assembly to t...

Страница 3: ...ration and Maintenance manual of the separately packaged MicroSilk hydrotherapy bath unit Full Support B ase Figure 3 Figure 4 WARNING SYSTEM UNDER PRESSURE NEVER PERFORM MAINTENANCE WHILE SYSTEM IS R...

Страница 4: ...ed following E T L Guidelines During installation if remote mounting of the blower is desired or required the following procedures should be followed NOTE Do not remote mount the blower more than 15 f...

Страница 5: ...Control Box The MicroSilk generator unit may be shippedseparatefromthebath Followtheinstructionsfor theMicroSilk PumpAssemblyFieldInstallationinthe Installation section of this owner s manual instruc...

Страница 6: ...Standard Premier Edition Signature Edition Sani Design C leaning Syst em B lower C ont rol B oxes C ont rol Mount L2 L1 GROUND DEDIC ATED 2 4 0 V 5 0 or 6 0 Hz GFC I PROTEC TED SERVIC E NOTE USE THE A...

Страница 7: ...e during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks 1...

Страница 8: ...f Ugtxleg Hgocng Pgoc Nqcf Eqppgevlqp MgCrcf aKFW 288b Dnqygt OU Swor Ocng Pgoc Nlpg Eqppgevlqp MgCrcf Ecdng aEDN 169b Transducer Cables Transducer Cables PqvguB C Ulping Fgflecvgf 120X 60JD 20C IHEK...

Страница 9: ...system see note B The MicroSilk pump s power cord should be plugged into the female cord connection on the ozone unit prewired to the control box C Eight pinmini DINterminalfortheMicroSilk AirMasseur...

Страница 10: ...B The MicroSilk pump s power cord should be plugged into the female cord connection on the ozone unit prewired to the control box C Eight pinmini DINterminalfortheMicroSilk AirMasseur Keypad D The bl...

Страница 11: ...ute pause before the purge cycle begins Once the purge cycle begins all indicators will light and the keypad operation will be disabled for two 2 minutes SIGNATURE EDITION MICROSILK AIRMASSEUR The Jas...

Страница 12: ...es 50mm above the jets The inlet temperature should not exceed 40 C 104 F When bath is in use turn the unit Off before draining the water The bath unit and its plumbing are designed to drain after eac...

Страница 13: ...gh speed mode Pressing the icon again begins the wave mode indicated by a slow flashing light Pressing the icon a third time will change the blower to pulse mode This is indicated by a rapid light fla...

Страница 14: ...2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a...

Страница 15: ...ll ensure a quick response on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment ALL WARRANTY...

Страница 16: ...a Refer to installer dealer b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make...

Страница 17: ...cted c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage a Check that bl...

Страница 18: ...er use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical histor...

Отзывы: