24
OPERATION
-
TIG
Before starting any welding activity ensure that you have suitable eye protection and
protective clothing. Also take the necessary steps to protect any persons within the welding
area.
TIG operation steps
Pulsed TIG
-
Continued
Select the peak current setting function by
pressing the parameter selection key until the
Ip LED Illuminates. The peak current range is
5~300amps and is adjusted via the control
knob and the amperage is shown on the front
panel digital display. The peak current
amperage can be adjusted during welding.
Select the base current setting function by
pressing the parameter selection key until the
Ib LED Illuminates. The base current range is
5~300amps and is adjusted via the control
knob and the amperage is shown on the front
panel digital display. The base current
amperage can be adjusted during welding.
Select the downslope time, crater current and post flow gas time as standard TIG.
Select the pulse duty cycle setting function by
pressing the parameter selection key until the
% LED Illuminates. The pulse duty range is
10~90% and is adjusted via the control knob
and the percentage is shown on the front
panel digital display. The pulse duty cycle can
be adjusted during welding.
Select the pulse frequency setting function by
pressing the parameter selection key until the
Hz LED Illuminates. The pulse frequency range
is 0.5~500Hz and is adjusted via the control
knob and the frequency is shown on the front
panel digital display. The frequency can be
adjusted during welding.
Select the spot time setting function by
pressing the parameter selection key until the
Tspot LED Illuminates. The spot time range is
0.1~10 seconds and is adjusted via the control
knob and the time is shown on the front panel
digital display.