OPERATION - TIG
Before starting any welding activity ensure that you have suitable eye protection and
protective clothing. Also take the necessary steps to protect any persons within the welding
area.
TIG operation steps
Select the DC TIG mode by pressing the welding mode selecting key.
Select the 2T mode by pressing the operation mode selecting key.
Select the pre flow time setting function by
pressing the welding parameter selecting key and
set the pre flow time.
Select the initial current setting function by
pressing the welding parameter selecting key and
set the initial current.
Select the upslope time setting function by
pressing the welding parameter selecting key and
set the upslope time.
Select the welding current setting function by
pressing the welding parameter selecting key and
set the welding current.