background image

Please Note:  Z-Wave home control networks are designed to work 

properly alongside 802.11 wireless computer networks, Bluetooth 

and other 2.4GHz or 5.8GHz devices.  Some baby cams, wireless video 

devices and older cordless phones using the 900MHz frequency range 

may cause interference and limit Z-Wave functionality.  Many 900MHz 

products have a switch to select channel “A” or “B”.  You may find that 

one of these channels will cause less interference than the other. 

Key Features:

— One Z-wave controlled AC outlet for standard incandescent 

lighting or dimmable CFL/LED

— Remote ON/OFF and Brightness control via the 

Z-Wave controller

— Manual ON/OFF and Brightness control with the front 

panel pushbutton

— Load-Sensing turns the light ON if the switch on the 

connected light is used instead of the remote or pushbutton 
on the Z-Wave module (default setting is disabled)

— One Always-ON pass-through AC outlet
— Space efficient design
— Does not block the lower outlet when plugged in to the 

upper outlet of a duplex wall receptacle.  (This assumes that 
the duplex receptacle is mounted with the ground pin down.) 

— Plugs and cords for connected devices route to the side 

allowing close placement of furniture

— Grounded 3-wire power connection for safety

Содержание ZW3103

Страница 1: ...Wireless Lighting Control On Off Dim Lamp Module Z Wave Certified Wireless Lighting Control 45702 ZW3103 Made in China ...

Страница 2: ... you want to do it all now or start with one room and add more over time This module is one component of a Z Wave control system and is designed to work with all other Z Wave enabled devices in a home control network It will also act as a wireless repeater to insure that commands intended for another device in the network are received thereby extending the range of the wireless controller Z Wave d...

Страница 3: ...f any CFL or LED will vary from bulb type to bulb type and among different manufacturers It is important to note that only bulbs that have been designed as dimmable should be used on a dimmer To find out if your bulb is dimmable please check the package the bulb itself or call the bulb manufacturer directly CAUTION To reduce the risk of overheating and possible damage to other equipment do not ins...

Страница 4: ...ntrol appliances Operation of the Z Wave device may be in a different room than the controlled appliance also an unintentional activation may occur if the wrong button on the remote is pressed Z Wave devices may automatically be powered on due to timed event programming Depending upon the appliance these unattended or unintentional operations could possibly result in a hazardous condition For thes...

Страница 5: ... remote or a Z Wave device and the destination device will reduce the maximum range by approximately 25 30 Brick tile or concrete walls block more of the RF signal than walls made of wooden studs and plasterboard drywall Wall mounted Z Wave devices installed in metal junction boxes will suffer a significant loss of range approximately 20 since the metal box blocks a large part of the RF signal 4 D...

Страница 6: ...ry From the Remote or repeating Z Wave module to destination device For Plug in Modules or In Wall Devices Installed in Plastic Junction Boxes Line of Sight no obstructions Type of Construction 0 1 Number of Walls or Obstacles 2 3 100 70 49 34 80 56 39 27 100 60 36 21 80 48 29 17 Wood Frame w Drywall Plastic J Boxes Metal J Boxes Plastic J Boxes Metal J Boxes Brick Tile or Concrete ...

Страница 7: ...dard incandescent lighting or dimmable CFL LED Remote ON OFF and Brightness control via the Z Wave controller Manual ON OFF and Brightness control with the front panel pushbutton Load Sensing turns the light ON if the switch on the connected light is used instead of the remote or pushbutton on the Z Wave module default setting is disabled One Always ON pass through AC outlet Space efficient design...

Страница 8: ... device This feature is disabled by default see the section on advanced operation for instructions on how to enable it Remote Control Jasco Z Wave remotes provide control of an Individual device Groups of devices and Scenes Other brands of Z Wave Certified remotes may not offer as much flexibility in how you can set up your lighting control network Please refer to your remote control s instruction...

Страница 9: ...nd include or exclude devices When prompted by your primary controller tap the button The primary controller should indicate that the action was successful If the controller indicates the action was unsuccessful please repeat the procedure Once the module is part of the network the same basic procedure is used to add the module to groups or scenes Refer to the primary controller s instructions for...

Страница 10: ... commands default It will not respond to ALL ON or ALL OFF commands It will respond to the ALL OFF command but will not respond to the ALL ON command It will respond to the ALL ON command but will not respond to the ALL OFF command Load Sensing Load sensing is disabled when shipped from the factory This feature can be enabled if desired Setting parameter 29 to a value of 1 will enable the Load Sen...

Страница 11: ...to go from maximum to minimum or minimum to maximum brightness levels 1 When Receiving a Z Wave Dim Command Parameter 7 number of steps or levels Parameter 8 timing of the steps Length 1 Byte Valid Values Parameter 7 default 1 Valid Values 1 99 Parameter 8 default 3 Valid Values 1 255 2 Manual Control Dimming pressing the Dimmer s button Parameter 9 number of steps or levels Parameter 10 timing of...

Страница 12: ...oad is automatically sensed by the module and all power to the load is shut OFF immediately Troubleshooting Verify that the lamp wattage does not exceed the 300W rating if the module doesn t seem to work properly Normal operation can be restored by remote when the load is reduced to the proper rating Over Current Protection Additional over current protection is provided by an internal fuse which i...

Страница 13: ...ng defects for a period of two years from the original date of consumer purchase This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product This warranty is in lieu of all other warranties expressed or implied Some states do not allow limitations on how long an implied war...

Страница 14: ...antee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment a...

Страница 15: ... B SPECIFICATIONS Power 120VAC 60Hz Signal Frequency 908 42 MHz Maximum load for both outlets 15A 1800W Resistive Maximum load for the Z Wave controlled outlet 2 5A 300 W Incandescent 100W Dimmable CFL LED Z Wave controlled outlet is fused 5A This fuse is not user serviceable Range Up to 100 feet line of sight between the Wireless Controller and the closest Z Wave receiver module Operating Tempera...

Страница 16: ... Road Oklahoma City Oklahoma 73114 Made in China Hecho en China All brand names shown are trademarks of their respective owners Todas las marcas que aparecen aquí son marcas registradas de sus respectivos dueños 2013 Jasco Products 45702 ZW3103 rev 08 19 13 ...

Отзывы: