ID
Name
Node Count
Profile
Function
1
Lifeline
5
General: Lifeline
Device Reset Locally Notification
Indicator Report
Switch Binary Report
2
Basic Set
5
Control: Key01
Basic Set
Number
Name
Information
Format / Size
Read
Only
Altering
Advanced
MIN
MAX
Default
0 3
Reaction of led
Change the reaction of the indicator.
1 byte unsigned integer
NO
NO
NO
0
3
1
41
Indicator brightness
Setting indicator's brightness.
1 bytes unsigned integer
NO
NO
NO
0
2
0
42
Restore status
Restore status after power failure.
1 bytes unsigned integer
NO
NO
NO
0
2
0
84
Reset factory
Set 1 to reset factory default
1 byte unsigned integer
NO
NO
NO
0
1
0
Basic Set Mapping
The Basic Set command is mapped to Binary Switch Set command.
The Basic Report command is mapped to Binary Switch Report command.
Indicator Command Class
Indicator ID
Property ID
0x50 (NODE IDENTIFY)
0x03(ON OFF PERIOD)
0x50 (NODE IDENTIFY)
0x04(ON OFF CYCLES)
0x50 (NODE IDENTIFY)
0x05(ONE TIME ON OFF PERIOD)
The indicator (blue color) will flashes according the indicator set command received from HUB.
Association Group
Endpoint ROOT
Configuration Parameters
ZWN4108 User Manual
No. 5 / 5