LTE910XF v6.00 CAT 1 Hardware User Guide JA20-UM-LTE-C1_v6 Page 4 Rev: 02 Date: 09/07/18
© Copyright 2018 Janus Remote Communications
Specifications subject to change without notice
All Rights Reserved See website for latest revision. Not intended for life support applications.
2. TECHNICAL SPECIFICATIONS
2.1 Electrical Specifications
2.1.1 Absolute Maximum Ratings
Parameter Signal
Signal
Maximum Rating
Main Power Supply
VCC
6.3V
I/O Voltage Reference
VREF
6.5V
2.1.2 Recommended Ratings & Module Pin out
2.1.2.1 Connectors J1 and J2
Pin
Name
Direction Description
Min
Typical
Max
If not used
1
VCC
Input
Main Power supply
3.5V
3.9V
5.5V
Must be implemented
VOL:
VOH:
Must be implemented
2
DOUT
Output
UART data out, I/O level tied to VREF
GND to
VREF x
if USB not used,
0.55V
0.67 to
No connection
VREF
VIL:
VIH:
Must be implemented
3
DIN
Input
UART data in, I/O level tied to VREF
GND to
VREF-0.4 if USB not used,
0.15V
V to VREF No connection
4
GND
Input
Ground Pin
0
Must be implemented
Controls HW_SHUTDOWN input on
Telit module, tie low for 200mS and
released to activate. Internally pulled
5 RESET_nIN
Input
up to VCC. Drive with open collector
VREF
No Connection
output. Assert only in an emergency
as the module will not gracefully exit
the cellular network when asserted.
6
VUSB
Input
Supply for USB interface
4.4V
5V
5.25V
No connection
7
USB_D+
I/O
USB differential Data + signal
No connection
8
USB_D-
I/O
USB differential Data - Signal
No connection
VIL:
VIH:
9
DTR
Input
Modem Data Terminal Ready input
GND to
VREF-0.4 Tie to GND
0.15V
V to VREF
10
GND
Input
Ground Pin
0
Must be implemented
11
GND
Input
Ground Pin
0
Must be implemented
VOL:
VOH:
12
CTS
Output
Modem Clear to Send hardware flow
GND to
VREF x
No Connection
control output
0.55V
0.67 to
VREF
Signal drives the onboard LED indicating
network status. OFF = Device OFF,
13 ON/nSLEEP Output
Fast blink = Searching for Network & Not
0
1.8V
No Connection
Registered, Slow Blink = Registered wtih
full service, Permanently on = call is
active. See Telit AT Commands Guide
for additional information.
Voltage reference for offboard I/O signals.
This signal drives the input voltage side
14
VREF
Input
of an onboard buffer which converts all
1.8V
1.8V or
5.5V
Must be Implemented
external I/O voltage from VREF range
3.3V
to 1.8V range to drive the onboard
Telit module.
15
GND
Input
Ground Pin
0
Must be implemented