6
Adjusting Presser Foot Height and Alignment
• The distance between the bottom of the presser foot in up position and the needle plate
should be 6.0 mm.
<To adjust>
Remove the face plate and needle.
Lower the feed dog below the needle plate. Place a block 6 mm thick under the presser foot
and lower the presser foot lifter.
Loosen the setscrew (A). Raise the presser foot lifter and tighten the setscrew (A) firmly.
Attach the needle and face plate.
Attach the face plate.
NOTE:
Make sure that the presser foot should be parallel to the feed dog slots (B) in the needle
plate.
Setscrew (A)
6mm
Presser foot height
Presser foot
Needle plate
Feed dog
Presser foot alignment
Presser foot should
be parallel to the feed
dog slots.
Block
(B)