16
ADJUSTMENT OF FEED DOG HEIGHT
When the presser foot is lowered with the pressure dial set at “ 3 “ the highest position of the
feed dog should be 0.75 to 0.85 mm above the top surface of the needle plate.
(1)
Set the pressure dial at “ 3 “ and lower the presser foot.
(2)
Turn the balance wheel until the feed dog comes to its highest position.
(3)
Detach the bed cover (unit).
(4)
Loosen the set screw (A) and nut.
(5)
Turn the adjusting screw so that the feed dog height is 0.75 to 0.85 mm above the top
surface of the needle plate.
(6)
Tighten the nut.
(7)
Tighten the set screw (A) and attach the bed cover (unit).
(Note)
For removal and attachment of the bed cover (unit), refer to page 4.
Содержание HD3000