18
TO ADJUST THE POSITION OF
THE CHAINING FINGER
Correct Setting:
When set the needle plate setting knob to the guide line S, the chaining finger should touch the side
of needle plate, and the tip of chaining finger should be same level with the tip of the needle on the
needle plate.
To adjust:
1. Remove the presser foot.
2. Set the needle plate setting knob to the guide line S on the chaining finger unit.
3. Loosen two setscrew A, and move the chaining finger unit to correct position.
4. Tighten two setscrew A.
5. Set the needle plate setting knob to the guide line S and R, and check the position of chaining
finger.
6. Attach the presser foot.
To be touched
Needle plate setting knob
Guide line S
Guide line R
Chaining finger unit
Setscrew A
Should be same level