6
CHanging exteRnal PaRts
fRont CoveR (1)
to Remove:
1. remove the face cover and free-arm cover (See page 8 and 9).
2. remove the SetScrewS (a)
q
(2 pcS.).
3. remove the SetScrewS (b)
w
(5 pcS.), back cover
e
.
4. remove the SetScrewS (c)
r
(2 pcS.).
5. looSen the SetScrew
t
.
6. diSconnect all the connectorS from the circUit board a.
note:
do not diSconnect the connectorS by pUlling on cord.
to diSconnect, graSp the connector, not the cord.
to attaCH:
7. follow the above procedUreS in reverSe.
q
w
w
w
r
r
e
t
thread tenSion
Unit
Содержание DC1050