13
5. Looper Height
The height of the tip of the looper should be 73.1 to
73.5 mm.
z
Remove the free arm cover (see page 4) and the
needle plate.
x
Replace the right needle with the short test pin
(28.3 mm long)
q
.
c
Turn the handwheel toward you to bring the looper
w
to its rightmost position.
v
Pull the looper release knob
e
and turn the looper to
the left.
Loosen the setscrew
r
and move the looper up or
down to match its point
t
with the tip
y
of the test
pin.
b
Tighten the setscrew
r
firmly.
n
Replace the test pin with a regular needle.
Attach the free arm cover and needle plate.
q
w
e
r
t
73.1 to 73.5 mm
y