Address     Meaning 

 

 

         Setting range     Pre-setting

080 

    M-Bus primary address (UMG96S) 

0 .. 250   

1

081 

    M-Bus baud rate 

1)

 

  0 

.. 

 5

082 

    Number of data points for RSP_UD2 

0 .. 39   

0

2)

083 

    As an extension secondary addr., Part 1  0 .. 99   

3)

084 

    As an extension secondary addr., Part 2  0 .. 99   

3)

085 

    As an extension secondary addr., Part 3  0 .. 99   

3)

086 

    As an extension secondary addr., Part 4  0 .. 99   

3)

1)

 0 = 300, 1 = 600, 2 = 1200, 3 = 2400, 4 = 4800, 5 = 9600, 6 = 19200, 7 = 38400 baud

2)

 0 = All data points. In order to call up all data points, two telegrams must be sent.

3)

 The extended secondary address is preset by the manufacturer with the device 

serial number.

Baud rate

The UMG96S can be operated on the M-bus interface with the following baud rates:
    300, 600, 1200, 2400, 4800, 9600, 19200 and 38400 baud.
The baud rate can be changed over the M-Bus.

Number of data points

Here you stipulate how many data points should be transmitted. Individual data 
points cannot be selected.

Example: Reading out the data points 1 to 6.
Enter a 6 into the UMG96S on address 82.
All data points, up to and including data point 6, are transmitted with every request.

Example: You require only the data point 10.
Enter a 10 into the UMG96S on address 82.
All data points, up to and including data point 10, are transmitted with every request.
Use only the data point 10 required and ignore the received but not required data 
points.

Содержание UMG 96S

Страница 1: ...Inbetriebnahme Description of functions M BUS BTR Version Art Nr 33 03 088 Janitza electronics GmbH Vor dem Polst ck 1 D 35633 Lahnau Support Tel 0 64 41 9642 22 Fax 0 64 41 9642 30 e mail info janitz...

Страница 2: ...hen Alle Markenzeichen und ihre daraus resultierenden Rechte geh ren den jeweiligen Inhabern dieser Rechte Kommentare zum Handbuch Ihre Kommentare sind uns willkommen Falls irgend etwas in diesem Hand...

Страница 3: ...E5 und REQ_UD2 RSP_UD2 Suche am M Bus Slave search Unterst tzt BTR Freeze Kommando Anwendungshinweise Das UMG96S kann mit verschiedenen Schnittstellen und den dazugeh rigen Pro tokollen eingesetzt wer...

Страница 4: ...4 Abb 1 UMG96S mit M Bus Schnittstelle Option RS232 M Bus M Bus Schnittstelle Option RS485 Deutsch...

Страница 5: ...t ber die 9 polige DSUB Buchse am UMG96S Verwenden Sie den mitgelieferten Stecker Schlie en Sie die ankommende Leitung M an die Klemme 4 im Stecker und M an Klemme 2 Eine eventuell weiterf hrende Busl...

Страница 6: ...51 bis 255 sind f r Spezialaufgaben reserviert Die Prim radresse kann ber den M Bus ge ndert werden Sekund radresse Die Sekund radresse besteht aus der erweiterten Sekund radresse und einem ger tespez...

Страница 7: ...te 1 bis 6 Geben Sie im UMG96S auf der Adresse 82 eine 6 ein Es werden bei jeder Anfrage alle Datenpunkte bis einschlie lich Datenpunkt 6 bertragen Beispiel Sie ben tigen nur den Datenpunkt 10 Geben S...

Страница 8: ...mA 10 0 3 4 7 Mittelwert Wirkleistung Phase L1 W 1 0 1 4 8 Mittelwert Wirkleistung Phase L2 W 1 0 2 4 9 Mittelwert Wirkleistung Phase L3 W 1 0 3 4 10 Mittelwert Spannung Phase L1 N mV 100 0 1 4 11 Mit...

Страница 9: ...nduktive Blindarbeit wenn der Niedertarif aktiv ist 20 Scheinarbeit VAh 10 0 2 6 21 Laufzeit Vergleicher 1a sek 1 0 1 4 22 Laufzeit Vergleicher 1b sek 1 0 2 4 23 Laufzeit Vergleicher 1c sek 1 0 3 4 24...

Страница 10: ...lw Strom Phase L2 0xB4 0x80 0x40 X 0xFD 0x59 6 Mittelw Strom Phase L3 0xB4 0xC0 0x40 X 0xFD 0x59 7 Mittelw Wirkleistung Phase L1 0xB4 0x40 X X 0x2B X 8 Mittelw Wirkleistung Phase L2 0xB4 0x80 0x40 X 0...

Страница 11: ...x40 X 0x24 X 24 Laufzeit Vergleicher 2a 0x84 0x80 0x80 0x40 0x24 X 25 Laufzeit Vergleicher 2b 0x84 0xC0 0x80 0x40 0x24 X 26 Laufzeit Vergleicher 2c 0x84 0x80 0xC0 0x40 0x24 X 27 Betriebsstundenz hler...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...r way without the legal written permission of Janitza electronics GmbH Vor dem Polst ck 1 D35633 Lahnau Germany Protected trademarks All trademarks and the resulting rights belong to the respective ow...

Страница 15: ...col types SND_NKE E5 and REQ_UD2 RSP_UD2 Search on the M Bus slave search Supports the BTR Freeze command Application information The UMG96S can be used with different interfaces and the corresponding...

Страница 16: ...16 English Illustration 1 UMG96S with M Bus interface Option RS232 M Bus M Bus inter face Option RS485...

Страница 17: ...s line Connection takes place using the 9 pole DSUB socket on the UMG96S Use the plug supplied Connect the incoming M line to terminal 4 in the plug and M to terminal 2 Connect M to terminal 9 and M t...

Страница 18: ...s and measured values M Bus Address The M Bus address consists of the primary address at least In addition the UMG96S can be accessed over the secondary address Primary address The M Bus subscriber ca...

Страница 19: ...urer with the device serial number Baud rate The UMG96S can be operated on the M bus interface with the following baud rates 300 600 1200 2400 4800 9600 19200 and 38400 baud The baud rate can be chang...

Страница 20: ...10 0 3 4 7 Mean value real power phase L1 W 1 0 1 4 8 Mean value real power phase L2 W 1 0 2 4 9 Mean value real power phase L3 W 1 0 3 4 10 Mean value voltage phase L1 N mV 100 0 1 4 11 Mean value vo...

Страница 21: ...6 Counts the inductive reactive energy when the low rate is active 20 Apparent energy VAh 10 0 2 6 21 Runtime comparator 1a sek 1 0 1 4 22 Runtime comparator 1b sek 1 0 2 4 23 Runtime comparator 1c s...

Страница 22: ...ase L2 0xB4 0x80 0x40 X 0xFD 0x59 6 Mean value current phase L3 0xB4 0xC0 0x40 X 0xFD 0x59 7 Mean value real power phase L1 0xB4 0x40 X X 0x2B X 8 Mean value real power phase L2 0xB4 0x80 0x40 X 0x2B...

Страница 23: ...24 Runtime comparator 2a 0x84 0x80 0x80 0x40 0x24 X 25 Runtime comparator 2b 0x84 0xC0 0x80 0x40 0x24 X 26 Runtime comparator 2c 0x84 0x80 0xC0 0x40 0x24 X 27 Operating hours counter 0x04 X X X 0x24...

Страница 24: ...24...