Safety information

Please read the operating instructions enclosed 
diligently, as well as all other publications that 
must be drawn upon for working with this 
measurement case and the accessories.

Observe all safety instructions and warnings. 
Failure to comply with the instructions can result 
in personal injuries and/or damage to the product.

The measurement case must only be operated by 
specialised personnel. Specialised personnel are 
persons, that based on their respective training 
and experience, are qualified to recognise risks 
and prevent potential dangers that can be 
caused by the operation or maintenance of the 
measurement case.

Check the measurement case, the measurement 
wires and accessory parts for any signs of 
damage before use. Check whether there are 
cracks in the plastic of any parts missing. Pay 
particular attention to the insulation of the wiring 
and connectors. Defective parts must be replaced 
immediately. Do not use if damaged! 

Comply with all of the locally applicable and 
national safety regulations. 
Use personal protective equipment (e.g. approved 
rubber gloves, face protection and protective 
clothing) in order to avoid electric shocks and 
burning injuries.

If the measurement case is not operated in 
accordance with the operation manual, protection 
is no longer ensured and hazards can be 
presented by the device!

Do not work with the device if the front plate 
has been removed. Otherwise, you may come 
into contact with hazardous voltages! It is not 
permitted to use the device with the front plate 
removed!

The UMG 512 is not suitable for 
measuring DC voltages.

Measured voltages and measured 
currents must derive from the same 
network. Voltages outside the rated 
range could destroy the measurement 
case.

Incorrect network settings can cause 
faults in the network.

m

- 3 -

Do not use the measurement case in 
wet or moist environments or in the 
vicinity of explosive gases or vapours.

Use the measurement case only with 
the measurement wires and adapter 
supplier.

Exercise particular caution when 
connecting and removing the flexible 
current transformers and the gripping 
probes for the measured voltage. 
Ensure that the circuit to be measured 
is de-energised.

Keep your fingers behind the finger 
protectors on the gripping measurement 
probes.

Voltages and currents that are outside 
the permissible measurement range
can destroy the device.

The input voltage shall not be 
higher than the rated voltage of the 
measurement device.

Disconnect the input signals before 
cleaning the measurement case.

c

c

Attention! Fatal hazard due to electrical energy: 

High voltage spikes that are dangerous to touch can occur on current transformers that 
are driven with open-circuit secondary windings! For this reason, never operate current 
transformers with open-circuit secondary windings! 

First connect the current transformer lines to the corresponding measurement case inputs!

Содержание MRG 512 PQ Flex

Страница 1: ...s GmbH Vor dem Polstück 6 D 35633 Lahnau Support tel 49 6441 9642 22 Fax 49 6441 9642 30 E mail info janitza com Internet http www janitza com www janitza com Mobile universal measurement device MRG 512 PQ Flex Supplementary description to the operation manual UMG 512 ...

Страница 2: ...ly basic device 4 Connecting the measurement case 4 Reading out recordings 5 MRG 512 PQ Flex views 5 Measurement transformer settings 6 Example connection voltage measurement 7 Example connection current measurement 7 Schematic diagram MRG 512 PQ Flex design 8 Technical data 9 2 ...

Страница 3: ...ce Do not work with the device if the front plate has been removed Otherwise you may come into contact with hazardous voltages It is not permitted to use the device with the front plate removed The UMG 512 is not suitable for measuring DC voltages Measured voltages and measured currents must derive from the same network Voltages outside the rated range could destroy the measurement case Incorrect ...

Страница 4: ... Janitza electronics GmbH Tel no 49 6441 9642 22 This device must only be operated and repaired by specialised personnel Connecting the measurement case 1 Connect the mains cable to the measurement case 1 and connect to 230 V 50 Hz Switch on the measurement case via the on off switch 2 The Mains OK 3 and Batt OK 4 LEDs illuminate 2 Carry out basic settings on the UMG 512 5 e g Voltage transformer ...

Страница 5: ...ement 2 Net Ok Batt Ok I O Differenzstrommess I 5 I 6 Eth AUX UMG 512 Netz Ok Batt Ok I O Residual current transformer I 5 I 6 Ether AUX U L1 U L2 U L3 U L4 U N L4 L1 L2 L3 N Spannungseingänge Differenzstrommessung I 5 I 6 I L1 I L2 Ethernet AUX I L3 I N Stromwandlereingänge L4 L1 L2 L3 N Voltage inputs Residual current transformer inputs I 5 I 6 I L1 I L2 Ethernet AUX I L3 I N Current transformer...

Страница 6: ... 400 A 6 630 A 5 1000 A 4 1500 A 3 2000 A 2 4000 A 1 Setting Rogowski coil 300 mm Flex CT 1A 300 mm Set the current measurement range with the DIP switch 2 in accordance with the table Potentiometer 1 DIP switch 2 6 The transformer ratio should be adapted in the UMG 512 measurement device too in accordance with the table Change the settings by means of the GridVis software or by entries on the dev...

Страница 7: ...th fuse Max 20mm Locking sleeve with bayonet catch for accommodating a fuse Example connection current measurement N L1 L2 L3 PE I1 I2 I3 IN I5 I6 Voltage measurement terms connections Rogowski coil RCM measurement cable Residual current transformer not included in the scope of deliverables ...

Страница 8: ...rrect setting of the current transformer check the performance values of the individual phases these must not possess any negative signs when drawing energy Also check the power factor for plausibility Turn the current transformer if necessary Up to 2 residual current measurements can be selected c Attention Fatal hazard due to electrical energy High voltage spikes that are dangerous to touch can ...

Страница 9: ...pply 230 V 50 Hz 50 VA Interface Ethernet Measurement inputs See UMG 512 operating instructions Measurements See UMG 512 operating instructions UPS buffering Up to 3 h Dimensions L x W x H 500 mm x 390 mm x 230 mm Weight 14 2 kg ...