18  Safety instructions

You have to take care anytime you operate the Combiflame! 

Never run the boiler without supervision. You may not leave the boiler unobserved if any door is 

opened. There is a risk of injury because of edges caused by the design of the boiler. Take care of 

this risk during transport and operating the boiler.  

You may not use any kind of easily inflammable substances like gasoline or ethyl alcohol to ignite 

the fire in the boiler. Please use BBQ charcoal lighter instead. 

After ignition every door of the boiler has to be kept close. Wear fire proved glows any time you open 

a door during heating. 

Do not open the front door until you have opened the start-up flap by pulling the lever on the right 

side of the boiler. After the opening of the flap you have to wait a couple of seconds before you may 

open the front door!

Use allowed fuels like wood pellets conform with 

EN 14961-2 A1, untreated wood and briquettes of 

brown coal only. You may not put any wood or brown coal into the boiler while the pellet burner is 

assembled. 

Cleaning should only happen if the boiler is cold.  

Never store any inflammable goods in front of the boiler. 

You may not dry any laundry or other inflammable goods on the surface of the Combiflame or the 

flue gas system. 

Содержание Combiflame

Страница 1: ...Janfire pelletsw rme swedish quality Janfire Combiflame Boiler for wood pellets log and brown coal manual...

Страница 2: ...lever on the right side of the boiler After the opening of the flap you have to wait a couple of seconds before you may open the front door 2 Warranty terms The warranty will only be issued on faults...

Страница 3: ...n or dirt in the hydraulic system Advanced claims are excluded especially any claim for damages if they are not founded by law If a warranty claim was not justified we will bring our costs to account...

Страница 4: ...d this manual Purchased parts package Boiler Combiflame including the catalytic converter four adjustable feet ash pit grill for operation with log pellet burner NH thermal controller for the draft fl...

Страница 5: ...23 24 25 26 27 28 connector female screw thread for thermal relief valve flue gas connector muffle 1 for backflow pellet burner thermostat safety relief switch main switch therm relif heat exchanger...

Страница 6: ...rn temperature C 55 flue gas average temperature mass flow cross section of flue gas connector average CO2 level in flue gas at nominal heat output average CO level 13 O2 at nominal heat output C g s...

Страница 7: ...ief heat exchanger The Combiflame has a welded thermal safety relief heat exchanger The thermal safety relief heat exchanger may not be used as a domestic hot water supply This heat exchanger has to b...

Страница 8: ...the maximal operation time adjustable in burner menu a fault message will appear in the display of the burner This case normally happens at the first start running or if you run out of pellets The in...

Страница 9: ...ong to the state of the art and work Ask local authorities before installation The heating room has to be conform to the local fire protection requirements If a ventilating system is installed make su...

Страница 10: ...r falls below the triggered temperature the burner will start again This kind of regulation is very inefficient and uncomfortable 8 2 2 Modulating operation The burner can be equipped with a modulatio...

Страница 11: ...em can be fount in chapter 4 No part of the flue gas system is allowed to be more tighten than the flue gas connector of the boiler A draft regulator is required This regulator is not part of the purc...

Страница 12: ...ic cold water supply But it is allowed to operate the boiler with pellets in this case The Combiflame is equipped with a built in thermal safety relief switch conform with EN 303 5 clause 3 21 In case...

Страница 13: ...ust them again if necessary 5 Connect the plugs of the burner according to the electric plan The electric connection has to be made according to the local terms by an expert The hose between the auger...

Страница 14: ...he connection between burner and auger system and the modulation sensor Open the screw hooks and remove the burner 6 Make sure that the burner and the hose will be stored properly The draft flap has t...

Страница 15: ...Start and adjust the burner as said in the manual Make sure that the ash pit is empty and the main heat exchanger and the catalytic converter are clean Do not open any door of the boiler during operat...

Страница 16: ...m thick bed of glow Than put the briquette on top of the glow There should be a distance from about 5 cm between the briquettes 3 The front grill has to be covered by the delivered cover sheet start u...

Страница 17: ...the front door until you have opened the start up flap by pulling the lever on the right side of the boiler After the opening of the flap you have to wait a couple of seconds before you may open the f...

Страница 18: ...an the main heat exchanger an the flue gas system every month cleaning of the grill Never use a vacuum cleaner to clean the grill There is a high risk of fire because of remaining glow Open the bottom...

Страница 19: ...mney too 17 Advice to averting of a danger To reduce risk you have to follow all instructions of this manual everytime you use this boiler autumn and spring The natural draft of the chimney depends on...

Страница 20: ...door of the boiler has to be kept close Wear fire proved glows any time you open a door during heating Do not open the front door until you have opened the start up flap by pulling the lever on the ri...

Страница 21: ...Janfire pelletsw rme swedish quality...

Отзывы: