background image

Jandy

®

 Pro Series Stealth

™ 

Pumps  

Models SHPF and SHPM

H0573800 Rev P

ENGLISH   

INSTALLATION AND 

OPERATION MANUAL

 WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and 

qualified in pool equipment by the jurisdiction in which the product will be installed where such state 

or local requirements exist. The maintainer must be a professional with sufficient experience in pool 

equipment installation and maintenance so that all of the instructions in this manual can be followed 

exactly. Before installing this product, read and follow all warning notices and instructions that accompany 

this product. Failure to follow warning notices and instructions may result in property damage, personal 

injury, or death. Improper installation and/or operation will void the warranty.

Improper installation and/or operation can create unwanted electrical hazard which can 

cause serious injury, property damage, or death. 

ATTENTION INSTALLER - This manual contains important information about the 

installation, operation and safe use of this product. This information should be given to 

the owner/operator of this equipment.

Содержание Stealth SHPF

Страница 1: ...of the instructions in this manual can be followed exactly Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning not...

Страница 2: ...2 Section 5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 13 Section 6 Troubleshooting 14 6 1 Troubleshooting 14 Section 7 Product Specifications and Technical Data 15...

Страница 3: ...without the test button being pushed a ground current is flowing indicating the possibility of electri cal shock Do not use the pump Disconnect the pump and have the problem corrected by a qualified...

Страница 4: ...o ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing Water pressure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 1...

Страница 5: ...eed the suction fitting assembly and it s cover s maximum design flow rate The suction outlet drain assembly and its cover must comply with the latest version of ANSI ASME A112 19 8 the standard for S...

Страница 6: ...r strength and corrosion resistance The pump is driven by an electric motor directly attached to the pump impeller As the electric motor turns it causes the impeller to turn which forces water to flow...

Страница 7: ...level isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing Some Safety Vacuum Release System SVRS de vic...

Страница 8: ...installation requirements NOTE To prevent entrapment the system must be built so that it cannot operate with the pump drawing water from only one 1 main drain At least two 2 main drains must be connec...

Страница 9: ...must be adequate to minimize voltage drop during the start up and operation of the pump See Table 2 for recommended wire sizes RECOMMENDED MINIMUM WIRE SIZE FOR SHP PUMPS Distance from Sub Panel 0 50...

Страница 10: ...ck hazard resulting in severe personal injury or death WARNING Due to the potential risk of fire electric shock or injuries to persons Jandy Pro Series Pumps must be installed in accordance with the N...

Страница 11: ...KS WARNING When pressure testing the system with water it is very important to make sure that the pump basket lid on the filter pump is completely secure WARNING Do not pressure test above 35 PSI Pres...

Страница 12: ...or a suction leak and then repeat Steps 2 through 7 Section 5 Service and Maintenance 5 1 Routine Maintenance Inspect the pump basket for debris by looking through the clear pump lid Remove any debris...

Страница 13: ...the o rings Drain Plug with O ring Set R0446000 3 Keep the motor covered and dry NOTE Covering the pump with plastic will create condensation and this moisture will damage the pump The best way to pro...

Страница 14: ...the lid o ring and place on the lid Hand tighten the lid to make an air tight seal Do not use any tools to tighten the lid Turn the pump back on Air leaks are still present Check the suction side pipi...

Страница 15: ...g Mech Seals SHPF 5 0 R0445201 3 Impeller Replacement Kit SHPF 50 R0807204 3 Impeller Replacement Kit SHPF 75 R0807203 3 Impeller Replacement Kit SHPF 1 0 1 0 2 R0807202 3 Impeller Replacement Kit SHP...

Страница 16: ...and Ceramic All R0479400 6 Body Pump SHPF SHPM All R0445601 7 Motor Mounting Foot Assembly w Screws SHPF SHPM All R0445700 8 Lid w Locking Ring Seal All R0445800 9 Blue Pressure Test O ring All R0479...

Страница 17: ...pecifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPF 50 50 208 230 115 4 4 4 5 8 8 2 2 30 lbs 311 8 SHPF 75 75 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPF 1 0 1 0 20...

Страница 18: ...SHPM 2 5 2 5 208 230 11 0 10 0 2 2 57 lbs 331 8 SHPM 1 5 2SPD 1 5 230 7 2 3 0 2 2 52 lbs 321 8 SHPM 2 0 2SPD 2 0 230 10 0 3 5 2 2 57 lbs 325 8 SHPM 2 5 2SPD 2 5 230 11 0 4 0 2 2 64 lbs 331 8 113 8 16...

Страница 19: ...NOTES Page 19 ENGLISH Jandy Pro Series Stealth Pumps Operation Manual...

Страница 20: ...ol Systems LLC 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com 2017 Zodiac Pool Systems LLC ZODIAC is a registered trademark of Zodiac International S A S U used under licens...

Отзывы: