Jandy SHPF Скачать руководство пользователя страница 9

Page 9

3.1.3 Pipe 

Sizing

NOTE

  All HP ratings given in this section apply to Full-

rated pumps. For help with max-rated pumps, 
contact Jandy Customer service.

3.1.3.1 Suction  Pipe

When the pump is located up to 50 feet from the 
pool, the recommended minimum pipe size for the 
suction side of the pump is 2" for ¾ to 1½ HP*. 
For 2 HP* pumps recommended pipe size is 2½". 
For 3 HP* pumps, recommended pipe size is 3".

* HP refers to full rated pumps

3.1.3.2 Discharge 

Pipe

When the pump is located up to 50 feet from the 
pool, the recommended minimum pipe size for the 
discharge side of the pump is 2" for ¾ to 1½ HP*. 
For 2 HP* pumps recommended pipe size is 2½". 
For 3 HP* pumps, recommended pipe size is 3".

* HP refers to full rated pumps

NOTE

  All pipe sizes are able to withstand the pressures 

the pump will deliver, but not the flow. If the pipe 
is too small for the pump, or it is elevated above 
water, the maximum gallons per minute (GPM) 
may not be delivered and the pump will make 
noise and shorten pump life. (cavitate)

3.1.3.3 Installation 

Recommendations

1.  If the pump is located below water level, 

isolation valves 

must 

be installed on both sides 

of the pump to prevent back flow of pool water 
during any routine or required servicing. 

2. 

To help prevent difficulty in priming, install the 
suction pipe without high points (above inlet of 
pump - inverted "U's" in plumbing), which can 
trap air. For installations of equipment up to 100 
feet from the water, refer to the pipe sizing chart, 
Table 1. For installations of equipment more than 
100 feet from the water, the recommended pipe 
must be increased to the next size.

Table 1. 

Pipe Sizing Chart for Schedule 40 PVC

Pipe 

Size

Maximum Flow 

Suction

(8 feet per second)

Maximum Flow 

Discharge

(10 feet per second)

1½"

50 GPM (189 LPM)

65 GPM (246 LPM)

2"

85 GPM (322 LPM)

105 GPM (397 LPM)

2½"

120 GPM (454 LPM)

149 GPM (564 LPM)

3"

184 GPM (697 LPM)

230 GPM (871 LPM)

3. 

Stealth Pumps come equipped with unions on 
both the suction and discharge ports. This feature 

simplifies installation, service, and eliminates 
the possibility of leaks at threaded adapters.

4. 

The Stealth Pump must be connected to at least 
two (2) hydraulically balanced main drains for 
each pool pump suction line. Each drain must be 
provided with covers that are listed or certified to 
ANSI/ASME A112.19.8. The suction fittings of 
the main drains must be at least three feet apart 
or at different planes. The suction fittings can be 
a drain and skimmer, two drains, two skimmers, 
or a skimmer with an equalizer line installed. 
Check the local codes for proper installation.

NOTE

  To prevent entrapment, the system must be built 

so that it cannot operate with the pump drawing 
water from only one main drain. At least two main 
drains 

must 

be connected to the pump when it is 

in operation. However, if two main drains run into 
a single suction line, the single suction line may 
be equipped with a valve which will shutoff both 
main drains from the pump.

5.  The piping must be well supported and not 

forced together where constant stress will be 
experienced.

6.  Always use properly sized valves. Jandy

®

 

Diverter Valves and Jandy

®

 Ball Valves typically 

have the best flow capabilities.

7.  Use the fewest fittings possible. Every fitting 

added has the effect of moving the equipment 
farther away from the water. 

NOTE

  If more than ten (10) suction fittings are needed, 

the pipe size must be increased. 

8. 

Every new installation must be pressure tested 
according to local codes. 

 WARNING

Do not pressure test above 35 PSI. Pressure 
testing must be done by a trained pool professional. 
Circulation equipment that is not tested properly 
will fail, which could result in severe injury or 
property damage.

 WARNING

Trapped air in system can cause pump lid to be 
blown off which can result in death, serious injury, 
or property damage. Be sure all air is properly 
out of system before operating. DO NOT USE 
COMPRESSED AIR TO LEAK OR PRESSURE 
TEST.

Содержание SHPF

Страница 1: ...llowed exactly Improper installation and or operation can create dangerous electrical hazards which can cause high voltages to run through the electrical system possibly causing death serious injury o...

Страница 2: ......

Страница 3: ...5 Service and Maintenance 12 5 1 Routine Maintenance 12 5 2 Winterizing the Pump 12 Section 6 Troubleshooting and Repair 13 6 1 Troubleshooting 13 6 2 Service Technician Maintenance 14 6 2 1 Blocked I...

Страница 4: ...h multiport slide or full flow valve position with the pump running WARNING The Jandy Pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or...

Страница 5: ...pump dry Running the pump dry for any length of time will cause severe damage and will void the warranty WARNING To minimize risk of severe injury or death the filter and or pump should not be subject...

Страница 6: ...pump can be connected to a single suction line as long as the requirements above are met Water Velocity The maximum water velocity through the suction fitting or cover for any suction outlet must be 1...

Страница 7: ...ed certified to ANSI ASME A112 19 8 Anti entrapment Cover Grate or Suction Fitting screw fastened to Main Drain Sump Listed certified to ANSI ASME A112 19 8 Anti entrapment Cover Grate or Suction Fitt...

Страница 8: ...recommended to install the pump within one 1 foot above the water level The pump should not be elevated more than a few feet above the water level of the pool A check valve is recommended on the sucti...

Страница 9: ...GPM 697 LPM 230 GPM 871 LPM 3 Stealth Pumps come equipped with unions on both the suction and discharge ports This feature simplifies installation service and eliminates the possibility of leaks at th...

Страница 10: ...3 2 3 Electrical Wiring 1 Thepumpmotormustbesecurelyandadequately grounded using the green screw provided Ground before attempting to connect to an electrical power supply Do not ground to a gas suppl...

Страница 11: ...ying all connections and clamps are secure according to the manufacturer s recommendations WARNING To avoid risk of damage or injury verify that all power is turned off before starting this procedure...

Страница 12: ...at all valves have been returned to the proper position for normal operation 8 Open the pressure release valve on the filter and make sure it is clean and ready for operation 9 Turn on the power to th...

Страница 13: ...he pump With clean union o rings hand tightening of the unions should create a seal If the unions still do not seal gently tighten with a large pair of tongue and groove pliers Do not over tighten The...

Страница 14: ...in order to access the inlet and outlet of the impeller 6 2 2 Impeller Removal WARNING While servicing the pump switch off the circuit breakers at the power source Severe personal injury or death may...

Страница 15: ...impeller center screw using a 3 Phillips screwdriver see Figure 5 NOTE The impeller center screw is a left hand threaded screw therefore turn the screw clockwise to loosen 8 Hold the motor shaft with...

Страница 16: ...TE Prior to replacing the lid check for debris around the lid o ring seat as this will cause air leaks into the system 9 Hand tighten the lid to make an air tight seal Do not use any tools to tighten...

Страница 17: ...quires that you replace the motor with the identical HP rating and service factor Jandy only 1 Have a qualified service technician or electrician properly disconnect the electrical wiring at the pump...

Страница 18: ...PM 2 0 1 1 R0445107 Motor 2 speed SHPM 2 5 1 1 R0445101 07 Bolts Washers All 4 4 2 R0445200 Backplate SHPF SHPM Mechanical Seal Carbon Mechanical Seal Ceramic O ring Bolts Washers All 1 1 1 1 8 8 3 R0...

Страница 19: ...ate All 1 14 R0446400 O ring Tail Piece All 2 15 R0446500 Diffuser Impeller Hardware Screw w O ring Self sealing Impeller Mounting Screw Diffuser Mounting Washer Diffuser Mounting O ring Diffuser All...

Страница 20: ...0 150 200 250 0 10 20 30 40 50 Feet of Head P S I Jandy Stealth Series High Head Pumps Full Rated SHPF and Max Rated SHPM Flow Rate GPM 2 HP SHPF 2 5 SHPM 3 HP SHPF 1 5 HP SHPF 2 0 HP SHPM 1 HP SHPF 1...

Страница 21: ...HPM Pump Specifications Model No HP Voltage Amps Pipe Size Carton Weight Overall Length A SHPM1 0 1 0 208 230 115 6 0 5 6 11 2 2 2 43 lbs 317 8 SHPM1 5 1 5 208 230 115 7 8 7 4 14 8 2 2 45 lbs 32 SHPM2...

Страница 22: ...Smith Century Pump Model A O Smith Century SHPF 75 B661 N A N A SHPF 1 0 B841 SHPM 1 0 B863SE SHPF 1 5 B842 SHPM 1 5 B864SE SHPF 2 0 B843 SHPM 2 0 B865SE SHPF 3 0 B844 SHPM 2 5 B866SE SHPM 2 0 2SPD B...

Страница 23: ...Page 23 NOTES...

Страница 24: ...and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals su...

Отзывы: