background image

HEATER IS OFF  

PRESS POOL OR SPA

Figure 3. AquaLink RS 485 
Communication (4-Wire 
Connection)

LXi CONTROLS QUICK GUIDE

Operating Modes

•  The LXi will heat the pool or spa only when 

the filtration system is running and the 

control has been turned on to either POOL 

or SPA as indicated by the enabled mode 

LEDs.

•  Maintain Temperature (Auto-Heat) will allow 

the heater to check the pool temperature 

periodically and override time clock 

settings, heating the pool or spa whenever 

the temperature falls below the set 

point. This feature on the heater requires 
additional field wiring. 

Normal Operation

•   Lit Jandy icon indicates unit has power. 
•   Choose Pool or Spa. Each has its own set 

temperature. The LXi includes the necessary 

controls to switch valves from pool to spa 

operation. 

•   Green enabled LED above icon will light. 
•   Temperature may be raised or lowered. 
•   Red LED above icon indicates unit is heating

User Set-up

With the unit in the OFF mode, press and 
hold the MENU key for 7 - 10 seconds. The 
UP & DOWN arrow keys toggle between the 
different functions. The MENU key toggles 
various options within the functions. The  
POOL & SPA keys end the Setup Mode and 
return to ‘OFF’.

User Set-up Functions

1)  

Language Selection

 

  Select from English, Spanish, French, Italian, 

Portuguese or German. 

2)  

Temperature Scale

  Select Fahrenheit or Centigrade scale.
3)  

Spa Timer

  Provides automatic shut down of spa 

operation.

4)  

Display Lighting

  Controller lights can be set ON, OFF or to 

SHUT OFF after a two minute delay.

Service Set-up Mode

From the off mode, press MENU, followed 

by POOL & SPA, holding all three buttons 

simultaneously for 7 - 10 seconds.

The UP & DOWN arrow keys toggle 

between the different functions. The MENU 

key toggles various options within the 

functions. The POOL & SPA keys end the 
Setup Mode and return to ‘OFF’.

Service Set-up Functions

1)  Maintain Temperature
2)  Maintain Temperature Delay 
3) Remote  
4) Freeze Protect
5) Louver
6) Load Defaults - Resets factory settings
7) Air Temperature Calibration
8) Water Temperature Calibration
9) Water Temperature Differential

10) Statistics
11) Last Fault

Maintain Temp Set-up Mode

Follow directions from Service Set-up Mode 

(see above), Maintain Temperature (Service 

Set-Up Function 1). To operate in pool 

mode with the Maintain Heat feature, press 

POOL, then press MENU, press the Down 

button until MAINTAIN POOL HEAT is 

displayed, press the MENU button.

The associated left green LED indicator 

will light and the unit will display SET:

XXXº. Change the temperature set point 

by pressing the Up or Down button until 

the desired set pint is displayed. After 5 

seconds of inactivity, the new set point is 

stored in memory.

LXi

Heaters

A Jandy LXi heater optional control can be installed 
remotely with 22AWG 4 conductor wire up to 300’. The 
additional control (p/n R3008800) can also be wired for 
control in the pool house or in the home. All wiring must 
be done in accordance with applicable local and National 
codes and requirements.

AquaLink RS/Remote Enable

Remote system must be wired as shown below 
before enabling the remotes options on the 
controller. 

Enter Remote Thermostat in Service Set-up Mode 
(#3 from Service Setup Mode functions). 

•  Display will show REMOTE on the second line. 

The UP/DOWN arrows will toggle to options: 
‘OFF’, ‘HI-LO-COM’, or ‘REMOTE T-STAT’. 

•  For Aqualink RS connection use ’REMOTE T-

STAT’, then MENU to save selection.

•  Select SPA. Raise heating setpoint, using UP 

arrow key, to maximum (104°F).

•  Control will indicate heater in Spa Heat mode and 

will alternately flash REMOTE T-STAT ENABLED.

•  For 3-wire remote systems select HI-LO-COM. 

Control will alternately flash REMOTE T-STAT 
ENABLED.

Figure 1. Remote Pool-Off-
Spa Connection (3-Wire 
Connection)

Figure 2. AquaLink RS or 
Remote TSTAT Connection 
(2-Wire Connection)

AquaLink RS 485

Remote system must be wired as shown before 
enabling the remotes options on the controller. 

•  Display will show JANDY REMOTE ONLINE 

PUSH MENU TO DISABLE, all control at the 
Heater is disabled.  

•  To temporarily use the Heater controls, press 

the MENU button. The display will disappear 
and all functionality will return to the Heater 
Control.

•  To return functionality to the RS unit, cycle the 

power to the Heater, or press the MENU button 
for 5 seconds to enter the User Setup Mode 
and then enable the Jandy Remote.

WARNING

TO AVOID PROPERTY DAMAGE, INJURY OR 
DEATH, BE SURE TO READ THE “

CONSUMER 

INFORMATION AND SAFETY” 

SECTION IN 

THE MODEL LXi HEATER INSTALLATION AND 
OPERATION MANUAL.

Отзывы: