Page 15
ENGLISH
Jandy
®
Pro Series JE Heat Pumps
|
Installation and Operation Manual
Figure 10. Jandy pro series JE Heat pump Front View
SERVICE ACCESS
PANEL (5 SCREWS)
CONNECTOR FOR
HIGH VOLTAGE WIRES
CONNECTOR FOR
LOW VOLTAGE WIRES
4.3
Bonding
Caution
This heater must be connected to a bonding
grid with a solid copper wire not smaller in
diameter than 8 AWG (In Canada, it shall be no
smaller than 6 AWG.)
The National Electrical Code
®
and most other U.S.
codes require that all metallic components of a pool
structure, including reinforcing steel, metal fittings,
and above ground equipment be bonded together with
a solid copper conductor not smaller than 8 AWG. The
heat pump, along with pumps and other pool equipment
must be connected to this bonding grid. A bonding lug
is provided on the right hand side of the heat pump to
ensure this requirement is met.
4.4
optional remote Controls
Electrical wiring must be in accordance with all
applicable national and local codes and ordinances.
Connection to a remote pool-off-spa selector
(3-Wire Connection)
install the remote pool-off-spa selector
1.
Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the screws that attach the service/access
panel to the heat pump unit and the cover to the
junction box (see Figure 10).
3.
Run the wires from the pool/spa control system
into the conduit connection labeled “Low Voltage
Connection”, located on the lower right hand side
of the heat pump (see Figure 10).
4.
Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(see Figure 11a).
5.
Restore power to the heat pump and the pool/spa
control system.
Configure the Control panel
1.
Make sure the control is in the
oFF
mode.
2.
To enter the Service Setup mode, press and hold
the
MEnu
,
pool
, and
spa
buttons for 5
seconds.
notE
The display will revert back to
oFF
after one
minute since the last key press.
3.
Press the
up
or
down
button to display
rEMotE
. Press the
MEnu
button. The
sElECt rEMotE oFF
(default remote)
appears, use the
up
or
down
button to scroll
through the Remote options. When you reach
Hi-
lo-CoM
, press the
MEnu
button to select the
remote. Press
pool
or
spa
to exit the Service
Setup mode.
Содержание JE
Страница 2: ......
Страница 4: ...Page 2 ENGLISH Jandy Pro Series JE Heat Pumps Installation and Operation Manual...
Страница 34: ......
Страница 36: ...Page 2 fran ais Thermopompes Jandy Pro de la s rie JE Manuel d installation et mode d emploi...
Страница 66: ......
Страница 68: ...P gina 2 ESPA OL Bombas de calor Jandy Pro serie JE Manual de Instalaci n y Operaci n...