background image

Page 10

         WARNING

NEVER 

attempt to assemble, 

dis as sem ble or adjust the 

fi

 lter when 

there is pressurized air in the system. 
Starting the pump while there is any 
pressurized air in the system can 
cause product failure or also cause 
the 

fi

 lter lid to be blown off, which can 

cause death, serious personal injury 
or property dam age.

8. 

While the DE 

fi

 lter grid assembly is out of the 

fi

 lter tank, rinse the inside of the tank with water. 

Replace drain plug. 

9. 

Gently rinse the grids with water. After cleaning 

the 

fi

 lter grids, place the grid assembly back into 

the 

fi

 lter tank bottom (see Sections 6.4 and 6.5 for 

further grid cleaning instructions).

10.  Replace the tank o-ring and tank lid.
11.  Reinstall the tank clamp ring. See Section 3.5 for 

tank clamp ring installation.

12.  If applicable, open the valves closed in step 4. 

5.2  Filter Grid Disassembly/Assembly

1. 

Remove the complete grid assembly by following 

the instructions in Section 5.1, steps 2-6. 

2. 

Remove the manifold by 

fi

 rst unscrewing the tie 

rod knob in the center of the manifold. Then lift 

the manifold assembly off of the grids and the 

outlet tube.

3. 

Remove the top spacer from the grids.

4. The 

individual 

fi

 lter grids can now be removed 

from the grid support. Use care to avoid damaging 

the grids.

5. 

See Figure 8 for the arrangement of 

fi

 lter grids in 

the 

fi

 lter grid assembly.

6. 

To reassemble the 

fi

 lter grid assembly, arrange 

the 

fi

 lter grids into position on the bottom plate 

(see Fig. 9). Use the plastic top spacer to hold 
the grids in place.

Table 3. 

Valve Positions for Diverter Valve

Position

Function

FILTER

Normal filtration and vacuuming.

BACKWASH

Cleaning filter by reversing the flow.

RINSE

Used after backwash to flush dirt 
from the valve.

WASTE

Bypasses filter; used for vacuuming 
waste or lowering water level.

RECIRCULATE

Bypasses filter for circulating water 
to the pool.

CLOSED

Shuts off all flow to the filter and 
pool.

Section 5. Filter Disassembly and 

Assembly

5.1 Filter Tank Disassemby/Assembly

1. Backwash 

fi

 lter according to the instructions in 

Section 6.2.

NOTE Omit this step when 

fi

 rst starting a new 

fi

 lter.

2. 

Turn off the pump. Switch off the circuit breaker 

to the pump motor.

3. 

IMPORTANT: Completely open air release valve 

on top of the 

fi

 lter tank to release all pressure 

from inside the tank and system. 

4. 

If the equipment is installed below water level, 

close the 

fi

 lter isolation valves on the system to 

prevent 

fl

 ooding. 

5. Close 

the 

fi

 lter isolation valves on the system to 

prevent 

fl

 ooding. Remove the drain plug located at 

the bottom of the 

fi

 lter tank and allow the tank to 

drain.

6. 

Remove the tank clamp ring from the 

fi

 lter and 

remove the tank lid. Inspect the tank o-ring for 

cracks or tears and replace if necessary

7. 

Pull the DE 

fi

 lter grid assembly out of the 

fi

 lter 

tank bottom. Use the handles molded into the 
manifold to aid lifting.

Figure 9.  Filter Grid Ar range ment

JANDY

PN

S0109500

OUTLET 
PIPE WITH 
O-RING

DEL  
FILTER 
GRID,
SHORT 
SPAN

DEL  FILTER GRID
(7 REQUIRED) 

BOTTOM PLATE

7. 

Inspect the o-ring at the top of the outlet tube for 

cracks or excessive wear. Replace if necessary.

8.   Assemble the manifold to the top of the assembly. 

Make sure that the grids and outlet tube 

fi

 t securely 

into the manifold and that the retaining rod extends 
up through the hole in the center of the manifold.

Содержание DEV Series

Страница 1: ...ficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly Before install ing this product read and follow all warning not...

Страница 2: ...bing 6 3 5 Clamp Installation DEV Series 7 Section 4 Start Up and Operation 8 4 1 Preparing Diatomaceous Earth 8 4 2 Coating the Filter Grids 9 4 3 New Pool and Seasonal Start up 9 4 4 Valve Operation...

Страница 3: ...etc is serviced air can enter the system and become pressurized when the system is restarted Pressurized air can cause product failure or also cause the filter lid to be blown off which can result in...

Страница 4: ...ion system should be designed to meet local health codes At a minimum the system should turnover the total volume of water in your pool two to four times in a 24 hour period 2 3 General Requirements 1...

Страница 5: ...tion and return lines to prevent back flow of pool water during any routine servicing that may be required 3 2 Anchor Bracket Installation In Florida building codes require that all appliances be secu...

Страница 6: ...nk located in the accessory bag 3 4 Filter Plumbing Figure 4 Basic Pool Spa Combination Plumbing Anchor Bracket Qty 4 12x1 Pan Head Screw Qty 8 Tank Bottom Filter Tank Anchor Bracket Installation Anch...

Страница 7: ...pes using the unions supplied with the filter Do not use teflon tape or pipe dope on any unions Assemble the unions dry and hand tighten CAUTION Be sure that all provisions for wastewater disposal mee...

Страница 8: ...s without use of diatomaceous earth DE DE is the substance that filters the water the filter cloth merely supports the DE Operating without DE will damage filter grids and shorten filtering cycles Cau...

Страница 9: ...e system and make sure that the filter drain plug is in place 5 Stand clear of the filter and start the pump to circulate water through the system When a steady stream of water starts to come out of t...

Страница 10: ...ion Function FILTER Normal filtration and vacuuming BACKWASH Cleaning filter by reversing the flow RINSE Used after backwash to flush dirt from the valve WASTE Bypasses filter used for vacuuming waste...

Страница 11: ...rod knob on the tie rod and tighten Tighten until the filter grid assembly is snug Do not overtighten 10 Reassemble the tank o ring and tank lid 11 Reinstall the tank clamp ring See Section 3 5 for cl...

Страница 12: ...otection when mixing the solution and handling or rinsing the filter grids 4 Soak for at least four 4 hours 5 Rinse the filter grids thoroughly with water 6 See Sections 5 1 and 5 2 for reassembly of...

Страница 13: ...p Check all lines for debris or partially closed valves Clean or replace filter grids per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Techni...

Страница 14: ...d Full Size DEV60 7 required R0359100 DE Grid Full Size DEV48 7 required R0555000 19 DE Grid Short Span DEV60 1 only R0359200 DE Grid Short Span DEV48 1 only R0554900 20 Tie Rod Knob R0359400 21 Ring...

Страница 15: ...DEV Series Filter Section 10 Head Loss Curves 10 1 Jandy DEV Filter Design Head Loss Curves 0 2 4 6 8 10 12 14 16 18 20 22 0 30 60 90 120 150 0 1 2 3 4 5 6 7 8 9 DEV48 DEV60 Design Head Loss ft head...

Страница 16: ...ZODIAC POOL SYSTEMS INC 6000 Condor Drive Moorpark CA USA 93021 800 822 7933 Fax 877 327 1403 2010 Zodiac Pool Systems Inc All rights reserved 1006 H0295200 Rev B...

Отзывы: