C artridge Pool Filters - C L and C V S eries Filters
nut and into the filter tank. Use the flats
on the tank adapter to tighten. Do not
overtighten.
b.
Place the larger, thinner o-ring onto the
gauge housing. Thread the housing into the
coupler on the tank adapter.
c. Orient the gauge/air release assembly in the
desired position. Raise and thread the locknut
onto the bottom of the gauge/air release
assembly. Hand tighten the nut only. Using
a wrench to tighten the nut may damage the
nut, gauge or air release assembly.
3.4 Filter Plumbing
1. This filter operates under pressure. When clamped
properly and operated without air in the water
system, this filter will operate in a safe manner.
2.
If the system can be subjected to higher pressure
than the maximum rating of any component,
install an ASME approved automatic pressure
relief valve or pressure regulator in the circulation
system. Set the relief valve or pressure regulator to
lowest working pressure of any of the components
in the system.
3. Place the filter on the concrete pad, lined up with
the inlet/outlet pipes (see Figures 5 and 5A).
4. To reduce pressure losses, 2" (minimum) piping is
recommended for plumbing the system.
5. For best efficiency use the fewest possible number
of fittings. This will prevent a restriction in the
water flow.
5.1 The CV model filter comes with a Jandy
Sweep Elbow for this purpose. The sweep
elbow also includes a threaded port and plug
so that a ½" hose bib can be connected for
pressure testing. See Figure 7.
5.2 To install the sweep elbow use the following
instructions:
W A RN I N G
T o a vo
i d a n e l e ct r i ca
l sh
o ck
h a za
r d , w h i ch
ca
n r e su
l t
i n se
r i o u s i n j u r y o r d e a t h , e n su
r e t h a t a l l e l e ct r i ca
l
p o w e r t o t h e syst
e m i s t u r n e d o f f b e f o r e a p p r o a ch
i n g ,
i n sp
e ct i n g o r t r o u b l e sh
o o t i n g a n y l e a ki n g va
l ve
s
o r p l u m b i n g t h a t m a y h a ve
ca
u se
d o t h e r e l e ct r i ca
l
d e vi ce
s i n t h e su
r r o u n d i n g a r e a t o g e t w e t .
W A RN I N G
F o l l o w a l l f i l t e r m a n u f a ct u r e r ' s
i n st r u ct i o n s.
N E V E R
a t t e m p t t o
a sse
m b l e , d i sa
sse
m b l e o r a d j u st t h e
f i l t e r w h e n t h e r e i s p r e ssu
r i ze
d a i r i n t h e
syst
e m . S t a r t i n g t h e p u m p w h i l e t h e r e
i s a n y p r e ssu
r i ze
d a i r i n t h e syst
e m ca
n
ca
u se
t h e f i l t e r l i d t o b e b l o w n o f f , w h i ch
ca
n ca
u se
d e a t h , se
r i o u s p e r so
n a l
i n j u r y o r p r o p e r t y d a m a g e .
a.
Switch off the circuit breaker to the
equipment and open the air relief valve on
top of the filter (leave it open during this
procedure).
N O T E
If the filter is below pool level, close the suction and
return line valves to isolate the filtration system.
Remove the drain plug from the filter. Let the water
drain from the filter.
Figure 4 .
Pressure G auge/ A ir Release A ssemb ly
H o u si n g
O - R i n g
O - R i n g
T a n k A d a p t e r
T a n k A d a p t e r t o H o u si n g
Co u p l e r
F i l t e r B a s e
D r i l l 5/ 32” H o l e
M o u n t i n g T a b
M o u n t i n g B r a c k e t
# 12x 1” S t a i n l e s s S t e e l P a n
H e a d S c r e w s ( Q t y 2)
D r i l l T w o 3/ 32” H o l e s
T h r o u g h F i l t e r B a s e
1/ 4” x 2- 1/ 4” S . S . T a p c o n
S c r e w a n d S . S . W a s h e r
3- 1/ 2” T h i c k
( M i n . )
Co n c r e t e P a d
A n c h o r
B r a c k e t
( Q t y 4)
# 12x 1” P a n H e a d
S t a i n l e s s S t e e l
S c r e w ( Q t y 8)
T a n k B o t t o m
F i l t e r T a n k A n ch
o r B r a cke
t I n st a l l a t i o n
A n ch
o r B r a cke
t t o P l a t f o r m I n st a l l a t i o n
Figure 3 .
A nc hor B rac k et I nstallation