background image

H

0

2

9

1

8

0

0

C

Installation and 
Operation Manual

Jandy

®

 Cartridge 

Pool Filters

CL and CV Versa-Plumb

Series Filters

  WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/
spa service technician. The procedures in this manual must be followed exactly. Improper 

LQVWDOODWLRQDQGRURSHUDWLRQFDQFUHDWHGDQJHURXVKLJKSUHVVXUHZKLFKFDQFDXVHWKH¿OWHU

lid to be blown off, possibly causing death, serious injury or property damage. Improper 
installation and/or operation will void the warranty.

Before installing this product, read and follow all warning notices and instructions that 

DFFRPSDQ\WKLV¿OWHU)DLOXUHWRIROORZZDUQLQJQRWLFHVDQGLQVWUXFWLRQVPD\UHVXOWLQ

property damage, serious injury, or death.

b

Installation and Operation Data

Содержание CL Versa-Plumb Series

Страница 1: ...proper LQVWDOODWLRQ DQG RU RSHUDWLRQ FDQ FUHDWH GDQJHURXV KLJK SUHVVXUH ZKLFK FDQ FDXVH WKH OWHU lid to be blown off possibly causing death serious injury or property damage Improper installation and...

Страница 2: ......

Страница 3: ...on 3 Installation Instructions 6 3 1 Filter Location 6 3 2 Anchor Bracket Installation 6 3 3 Filter Preparation 6 3 4 Filter Plumbing 7 3 5 Clamp Installation 10 Section 4 Start Up and Operation 10 Se...

Страница 4: ...ing system i e filter pump valve s clamp etc is serviced air can enter the system and become pressurized when the system is restarted Pressurized air can cause the filter lid to be blown off which can...

Страница 5: ...ol two to IRXU WLPHV LQ D KRXU SHULRG 2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 7KH OWHU VKRXOG EH ORFDWHG RQ D OHYHO FRQFUHWH slab so t...

Страница 6: ...da building codes require that all appliances be securely fastened to the equipment pad in order to withstand high wind pressures created by hurricanes Jandy provides an anchor bracket kit for this pu...

Страница 7: ...FDQ EH FRQQHFWHG IRU pressure testing See Figure 7 5 2 To install the sweep elbow use the following instructions WARNING To avoid an electrical shock hazard which can result in serious injury or deat...

Страница 8: ...Valve From Outlet Port To Inlet Port Jandy Filter Figure 5A CV Cartridge Filter Plumbing for Pool Spa Combination Jandy Heater Waterfall Pool Return Spa Make Up Spa Return From Pool Skimmer From Pool...

Страница 9: ...KHFN IRU SURSHU ZDWHU RZ 6 Make all plumbing connections in accordance with local plumbing and building codes Filter connections are provided with an o ring seal To avoid damage to the o rings use onl...

Страница 10: ...ully counterclockwise do not remove the knob H VXUH WR RSHQ DQ OWHU LVRODWLRQ YDOYHV WKDW were installed in the system 7 6WDQG FOHDU RI WKH OWHU and start the pump to circulate water through the syste...

Страница 11: ...rs the cartridges on the inside of the tank 8 Remove the manifold assembly by lifting it off of the outlet tube and out of the tank 3XOO WKH FDUWULGJHV RXW RI WKH OWHU WDQN DQG FOHDQ the cartridge usi...

Страница 12: ...GR DQ ZRUN RQ WKH OWHU SXPS V VWHP CAUTION Maintain your pressure gauge in good working order The pressure gauge is the primary indicator of how the filter is operating Section 7 Winterizing 1 Turn of...

Страница 13: ...osed valves Clean or replace filter cartridges per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Technician required Replace baskets Technicia...

Страница 14: ...LOWHU DUWULGJH VT IW UHTXLUHG 5 11 Tank Clamp Ring w Rod Assembly All 5 12 Threaded Rod and Retainer All 5 Tank O ring All 5 Outlet Tube Elbow Assembly w O rings All 5 Inlet Elbow w O ring All 5 Filte...

Страница 15: ...Page 15 Cartridge Pool Filters CL and CV Series Filters 19 21 21 20 21 15 21 21 18 21 14 23 19 22 20 22 22 15 22 14 23 16 16 22 18 21 22 9 2 Jandy CL and CV Filters Exploded View CL Filter CV Filter...

Страница 16: ...ion 10 Head Loss Curves 10 1 Jandy CL and CV Cartridge Filter Design Head Loss Curves 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 30 60 90 120 150 Flow Rate gpm Design Head Loss ft head 0 2 4 6 8 10 12...

Страница 17: ...Page 17 Notes Cartridge Pool Filters CL and CV Series Filters...

Страница 18: ...Page 18 Notes Cartridge Pool Filters CL and CV Series Filters...

Страница 19: ...Page 19 Notes Cartridge Pool Filters CL and CV Series Filters...

Страница 20: ...published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanit...