Section 1. Safety Information

1.1 Important 

Safety 

Warning

1.      Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment of the clamp, or 

any other service of the circulating system; (A) 

turn the pump

 

off

 and shut off any automatic controls to ensure 

the system is not inadvertently started during servicing; (B) open the air release valve; (C) wait until all pressure 
is relieved (air will have stopped fl owing from the air release valve).

2.      Whenever installing the fi lter clamp 

follow Section 3.4 

of this manual

, "Clamp Installation".

3.      Once service on the circulation system is complete, 

follow Section 4 

of this manual

, "Start-up and 

Operation"

4.      Maintain circulation system properly. Replace worn or damaged parts immediately.

5.      Be sure that the fi lter is properly mounted and positioned according to these installation instructions.

6.      Do not pressure test above 50 PSI. Pressure testing must be done by a trained pool professional. 

SAVE THESE INSTRUCTIONS.

ATTENTION INSTALLER:

This manual contains important information about the installation, operation and safe use of this 
product. This information should be given to the owner/operator of this equip ment.

1.2  General Safety Instructions

WARNING

NEVER OPERATE OR TEST THE FIL TER SYSTEM AT MORE THAN 50 PSI.

THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE 
CIRCULATING SYSTEM, i.e., FILTER, PUMP, VALVE(S), CLAMP, ETC. IS SERVICED, 
AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED WHEN THE SYSTEM IS 
RESTARTED. PRESSURIZED AIR CAN CAUSE THE FILTER LID TO BE BLOWN OFF 
WHICH CAN RESULT IN DEATH, SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE. 
TO AVOID THIS PO TEN TIAL HAZ ARD, FOL LOW ALL OF THE IN STRUC TIONS IN THIS 
MAN U AL.

Содержание CL Series

Страница 1: ...tallation and or operation can create dangerous high pressure which can cause the lter lid to be blown off possibly causing death serious injury or property damage Improper installation and or operati...

Страница 2: ......

Страница 3: ...ion 5 2 2 Description 5 2 3 General Requirements 5 2 4 Speci cations and Dimensions 5 Section 3 Installation Instructions 6 3 1 Filter Location 6 3 2 Filter Preparation 6 3 3 Filter Installation 7 3 4...

Страница 4: ...tely 5 Be sure that the lter is properly mounted and positioned according to these installation instructions 6 Do not pressure test above 50 PSI Pressure testing must be done by a trained pool profess...

Страница 5: ...ool two to four times in a 24 hour period 2 3 General Requirements 1 For best overall performance place the system as close to the pool as possible 2 The lter should be located on a level concrete sla...

Страница 6: ...it can be raised 2 5 ft without affecting the pump ef ciency A check valve is recommended on the suction line to the pump 8 If the lter is to be installed below the water level of the pool isolation...

Страница 7: ...all plumbing connections in accordance with local plumbing and building codes Filter connections are provided with an o ring seal To avoid damage to the o rings use only a silicone base lubricant on t...

Страница 8: ...ch each other or are within 1 16 See Fig 6 but do not overtighten as the clamp can break If unable to tighten as indicated do not operate the lter and call a service technician immediately 5 After the...

Страница 9: ...ee Section 6 3 This indicates an increased pressure of between 10 and 12 psi above original starting pressure Section 5 Filter Disassembly and Assembly 1 Turn off the pump Switch off the circuit break...

Страница 10: ...duct user should contact either the product manufacturer or some other source to determine means for obtaining replacement signs or labels 7 Installation of new replacement safety signs or labels shou...

Страница 11: ...lves Clean or replace filter cartridges per instructions Fill pool so level is above pump inlet line Fill pump with water at basket and replace lid Technician required Replace baskets Technician or el...

Страница 12: ...ob Assembly R0357400 12 Clamp Ring Knob Assembly w Threaded Rod and Retainer R0357500 13 Tank O ring R0357800 14 CL580 Outlet Tube Elbow Assembly w O rings R0358100 CL460 CL340 Outlet Tube Elbow Assem...

Страница 13: ...Page 13 Cartridge Pool Filters CL Series Filter Section 10 Head Loss Curves 10 1 Jandy CL Cartridge Filter Design Head Loss Curves...

Страница 14: ...Page 14 NOTES...

Страница 15: ...Page 15 Cartridge Pool Filters CL Series Filter...

Страница 16: ...rates outside the published minimum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or imp...

Отзывы: