Jandy Pumps HHPU Series Скачать руководство пользователя страница 16

Water Pik Technologies, Inc.

Page 16

Key

 Size

 ORDER

No.    Description

(HP)

PART NO:

50 Motor, Full Rated, MHP Series

.75

R0339701

50 Motor, Full Rated, MHP Series

1.0

R0339702

50 Motor, Full Rated, MHP Series

1.5

R0339703

50 Motor, Full Rated, MHP Series

2.0

R0339704

50 Motor, Up-Rated, MHPU Series

.75

R0339801

50 Motor, Up-Rated, MHPU Series

1.0

R0339802

50 Motor, Up-Rated, MHPU Series

1.5

R0339803

50 Motor, Up-Rated, MHPU Series

2.0

R0339804

50 Motor, Up-Rated, MHPU Series

2.5

R0339805

51 Mounting Bracket

All

R0339900

52 Impeller, MHP Series

.75

R0340002

52 Impeller, MHP Series

1.0

R0340003

52 Impeller, MHP Series

1.5

R0340004

52 Impeller, MHP Series

2.0

R0340005

52 Impeller, MHPU Series

.75

R0340001

52 Impeller, MHPU Series

1.0

R0340002

52 Impeller, MHPU Series

1.5

R0340003

52 Impeller, MHPU Series

2.0

R0340004

52 Impeller, MHPU Series

2.5

R0340005

53 Diffuser

All

R0340100

5

Mechanical Seal

All

R0338200

54 Body, Pump Face Assy.

All

R0340200

55 Mounting Foot Assy.

All

R0340300

8

Pot Lid

All

R0338500

9

Pot Basket

All

R0338600

56 O-ring, -259, Body

All

R0340400

13 O-ring, -330, Diffuser

All

R0338800

14 O-ring, -359, Pot Lid

All

R0338900

57 Hardware Set (3), Mntg. Diffuser

1

All

R0340500

23 Drain Plugs (2)

All

R0339100

58 Hardware Set (2), Mntg. Foot

1

All

R0340600

59 Hardware Set (4) Mntg. Motor

1

All

R0340700

27 Coupling Nut Set

All

R0339500

28 O-ring, -332 (2), Coupling Set

All

R0339600

O-ring Set, Complete (6)

All

R0341100

Hardware Set, Complete

All

R0341200

NOTES:

1.

All hardware sets contain all pieces necessary for assembly.

2.

All replacement kits include all hardware and o-rings needed to
replace the ordered part.

To order or purchase parts for Jandy™ Pumps,

contact your nearest Water Pik Technologies Products
dealer or distributor. If they cannot supply you with
what you need, contact the Customer Service Manager
at Water Pik Technologies, Inc.

10B. Jandy™ MHP & MHPU Pump Series

Содержание HHPU Series

Страница 1: ...pa installation Improper installation and or operation can create an electrical hazard which can cause serious injury property damage or death Improper installation and or operation will void the warr...

Страница 2: ......

Страница 3: ...d Maintenance 7A General Maintenance 8 7B Winterizing the Pump 9 SECTION 8 Troubleshooting 8A Troubleshooting 9 SECTION 9 Speciality Service 9A Blocked Impeller 10 9B Removing the Pump Housing 11 9C R...

Страница 4: ...y Pumps must be installed in accordance with the National Electric Code all local electrical and safety codes and the Occupational Safety and Health Act OSHA Copies of the National Electrical Code may...

Страница 5: ...and electrical cost savings Since the pump should be operated at low speed for cost savings minor adjustments may be required in the automatic chlorine dispenser the skimmers and the heater due to th...

Страница 6: ...without high points which can trap air For installations up to 100 feet from the water the recommended pipe size must be used For installations more than 100 feet from the water the recommended pipe m...

Страница 7: ...me clock well away from the pool pump filter and other equipment for safety reasons Should there be an equipment failure or loose fitting access to the switch away from the failed equipment is importa...

Страница 8: ...Installation for proper elevation and pipe size 12 If the pump does not prime and all the instructions to this point have been followed check for a suction leak SECTION 7 Use and Maintenance 7A Genera...

Страница 9: ...chnician or electrician properly disconnect the electrical wiring at the switch or junction box Once the power is removed the two unions can be loosened and the pump stored indoors For safety and to p...

Страница 10: ...be within 10 of the motor s nameplate rating If it is not then a qualified electrician and or the power company needs to get involved to resolve the problem c Pump seal is leaking air Have a qualified...

Страница 11: ...way Be careful not to lose or damage the o rings The impeller is connected to the motor side of the pump 5 Remove the diffuser o ring It may be stuck on the pump body nozzle 6 Using a No 2 Phillips sc...

Страница 12: ...and right 6 There is an o ring located between the diffuser and the pump body Place the diffuser o ring over the diffuser s suction side See Fig 5 7 Check for debris around the pump body o ring seat a...

Страница 13: ...tween the rubber and the plastic impeller as this will damage the impeller See Fig 6 3 Lubricate water the perimeter of the new seals rubber gasket 4 Press the ceramic assembly onto the Impeller 5 Use...

Страница 14: ...Diffuser 75 2 0 R0338801 13 O ring 330 Diffuser 3 0 R0338805 14 O ring 359 Pot Lid All R0338900 15 Hardware Set 4 Diffuser Mntg 1 All R0339000 23 Drain Plugs 2 All R0339100 24 Hardware Set 2 Foot Mnt...

Страница 15: ...Page 15 Jandy Pumps 9 8 14 6 13 4 23 24 15 3 7 12 25 5 26 2 1 27 27 28 28 Figure 9 HHP Exploded View...

Страница 16: ...R0340005 53 Diffuser All R0340100 5 Mechanical Seal All R0338200 54 Body Pump Face Assy All R0340200 55 Mounting Foot Assy All R0340300 8 Pot Lid All R0338500 9 Pot Basket All R0338600 56 O ring 259...

Страница 17: ...Page 17 Jandy Pumps 50 51 59 55 56 5 52 53 58 57 13 54 28 27 23 28 27 8 14 9 Figure 10 MHP MHPU Exploded View...

Страница 18: ...Pump Curves Flow GPM 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Jandy High Head Pumps Full Rated HHP Up Rated HHPU 0 10 20 30 40 50 60 70 80 90 100 110 120 Feet of Head 5 10 15 20 25 30 35 40 4...

Страница 19: ...es Jandy Medium Head Pumps Full Rated and Up Rated MHPU MHP Feet of Head P S I Flow GPM 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 0 10 20 30 40 50 60 70 80 5 10 15 20 25 30 35 1 5MHP 2 0MHPU 1...

Страница 20: ...10 9 4 3 8 9 7 8 7 5 8 11 5 8 5 C L MODEL HP VOLTAGE PIPE CARTON DIMENSIONS NO SIZE WEIGHT A B HHP 75 75 115 230 2 38lbs 23 13 HHP1 0 1 0 115 230 2 41lbs 23 13 HHP1 5 1 5 115 230 2 47lbs 24 14 HHP2 0...

Страница 21: ...L A B 10 9 8 10 C L MODEL HP VOLTAGE PIPE CARTON DIMENSIONS NO SIZE WEIGHT A B MHP 75 75 115 230 2 38lbs 23 13 MHP1 0 1 0 115 230 2 41lbs 23 13 MHP1 5 1 5 115 230 2 47lbs 23 13 MHP2 0 2 0 230 2 51lbs...

Страница 22: ......

Страница 23: ......

Страница 24: ...or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and...

Отзывы: