FAULT FINDING TABLE 

SYMPTOM 

CAUSE 

REMEDY 

E101 totally dead eg 
switches do not illu-
minate, no sound in 
the headsets, and 
no response to but-
ton presses 

System power off 

Check Master power 
switch 

Mains power failure, power 
turned off at wall socket or 
disconnected 

Check connections of 
Master 

Disconnection/not plugged 
in 

Check connections be-
tween Master and belt-
pack 

Faulty cable or other 
equipment in the system 

Disconnect stations from 
master until the system 
works 

Faulty Master 

Repair/replace 

Faulty E101 

Repair/replace 

E101 mic keeps 
switching off 

Faulty cable or Master 

Repair/replace 

Operator at Master pressing 
“Remote mic disable” switch 

Liaise with operator of 
Master 

No sound in headset  Volume turned down 

Turn up volume  

No one talking 

Nothing to fix here 

Faulty headset 

Swap with another set 

Faulty cable 

Repair/replace 

Distorted sound 

Volume too high 

Turn volume down 

Faulty headset 

Replace headset. Avoid 
single-ear headsets 

Ambient noise level too high  

  Turn unused mics off 

  Relocate operator posi-

tion 

Users talking too loudly 

Liaise with other users 

Table 7.1 – Fault Finding Table

 

 

 

7

 

CLEANING AND MAINTENANCE 

To keep the E101 clean use a mild detergent and water with a soft cloth or paper towel, 
taking care to avoid water entering the units.  

There are no user-serviceable parts inside. 

 