background image

e.

       

Details concerning cleaning and other maintenance

f.

 

Maintenance of water purity, especially PH values and chlorine concentrations.

g.

       

Cleaning and disinfection

h.

       

Use and installation of a cover.

i.

 

Disposal of water

j.

 

Precautions to avoid damage due to water freezing

k.

       

Precautions to avoid damage when the appliance is left empty for extended period.

     
     

2.2 Sub-clause 7

     The installation instruction shall state the substance of the following:

-

   

Earthed appliances must be permanently connected to fixed wiring;

-

   

The appliance should be supplied through a residual current device (RCD) having a rated residual 

operating current not exceeding 30 mA.

-

   

The floor has to be capable of supporting the expected load.

-

   

An adequate drainage system has to be provided to deal with overflow water.

-

   

Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct zone 

and that equipotential bonding is carried out.

WAR

NING

1

DANGER

RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a

Ground Fault Circuit lnterrupter.

2

Grounding is required. The unit should be installed by a qualified service representative and

ground.

3

FOR YOUR SAFETY-This product should be installed by a professional service 

   technician,qualified in hydrotherapy bath installation.
4

lt’s prohibited to cover the instrument with something while opeating.

5

when using at the first time ,Be sure there is water in heater pipe before staring.

6

parts containing live parts, except parts upplied with safety extra-low voltage not  Exceeding

12V,must be inaccessible to person in the bath

8

earthed appliances must be permanently connected to fixed wiring

9

the appliance should be supplied through a residual current device (RCD)having a rated

residual operating current not exceeding 30 mA.

1

0 、

If  the mains cord of this appliance is damaged,It must only bereplaced  by our service

representative,As special tools and/or parts are required

Solutions of Fault

Phenomenon

Reason

How to Solve the problem

11

Содержание SPA-565

Страница 1: ...HOT TUB Model SPA 565 OPERATING INSTRUCTION 1...

Страница 2: ...ower On off or Switch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump2 On off Lasting Circulation Cleaning On off Surfin...

Страница 3: ...ircuit display 1 When you first start the spa the backlight will be dimmed and the LCD will show the current time and temperature If there is a problem with the circuit board the controller will displ...

Страница 4: ...5 Circulation cleaning off Fig 6 Circulation cleaning on When setting the Circulation cleaning the display must be in the Power off status and the LCD display 1 Press to enter Circulation cleaning set...

Страница 5: ...each time The maximum working time is 19hours and 55 minutes When you have completed this procedure continue to the next setting 4 If all settings have been correctly set Press for confirmation the s...

Страница 6: ...res whether pre heating settings are set or not See following Fig 7 8 ON OFF Fig 7 Pre heat On 8 Pre heat Off Pre heating is set when the spa is in the Power off status and the LCD display shows 1 Set...

Страница 7: ...ress SET VOL again It will show SET on the LCD panel Press button to change the setting temperature The range of temperature setting is 15 40 5 When everything is set correctly press the to confirm th...

Страница 8: ...the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozone works at every 15 minutes During the preheating the Circulation cleaning will be turned off...

Страница 9: ...ill memorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 The volume can be changed by pressing key SET VOL and OPEN 11 Operation of Pump The Button...

Страница 10: ...pa is on normal power supply IV Electric parameters 1 Performance index Rated voltage 220V 50Hz Maximum working current 60 A 220V 240V Voltage resistance 1250V 1 minute without penetration Isolative r...

Страница 11: ...potential bonding is carried out WAR NING 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit lnterrupter 2 Grounding is required The unit should be installed...

Страница 12: ...3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug of the temperature detector be...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Отзывы: