phone: 1-800-854-3140 | 1-503-304-8899 fax: 1-800-366-7505 | 1-503-304-1899 www.jjamusements.com
3-25
SOLID STATE SWITCH
The solid state switches are completely sealed and utilize magnetic triggers to turn on a low-amperage circuit and energize
the pull-in windings of the motor relay, or activate the squirt pump. These have a built-in LED light that serves as a self-
diagnostic tool to aid in troubleshooting these devices.
This sealed solid state switch is triggered on and o
ff
by the proximity of a neodymium magnet located in the magnetic
trigger housing (see page 3-19).
The function of the solid state switch is dependent upon the proximity of the magnet to the switch.
NOTICE:
When replacing the magnetic trigger or anything else in this area, be sure to orient the magnet trigger magnet
side down so it can function properly.
During normal operation, the LED will light when the switch is “ON”.
Symptom: The light is on all the time, even when the switch is not activated.
Most common cause: The solid state switch is wired incorrectly, or the magnetic trigger is too close to the switch, not
allowing the switch to turn o
ff
.
NOTICE:
If the solid state switch has been wired incorrectly, major damage will occur.
Solutions: The switch is defective and must be replaced.
Symptom: The light is o
ff
all the time, even when the switch is in the “ON” position.
Most common cause: No voltage to the switch.
Solutions: Verify that there is voltage the to switch.
General Information .......................................................... 3-25
Solid State Switch ............................................................... 3-26