Thank you for purchasing the PETRA Whirlpool Pedicure Spa. This finest Whirlpool Pedicure Spa has 
been developed by J&A USA, Inc. to operate dependably for many years when used properly. Please 
take time to read this entire manual thoroughly before installation and use. 

 

PLEASE READ AND FOLLOW INSTRUCTIONS CAREFULLY!

 

 

Important Precautions 

 

J&A USA requires that you contact your local, qualified electrician and plumber to install your PETRA 
Whirlpool Pedicure Spa. It cannot operate efficiently or safely unless it is provided with adequate 
electrical power, sufficient water pressure, proper water temperature and required drain facilities. 
Information on these important subjects contained in this manual. We urge you to read it carefully 
to make sure these requirements are met. 

 

Precautions 
 

1 Excessive water temperature is dangerous and should be checked before use.   Maximum water 
temperature should not exceed 100 deg. F. (38 deg. C.). 
2 Always enter and exit the Whirlpool Pedicure Spa slowly and carefully. 
3 Never bring and/or operate any electrical devices into or near the Whirlpool Pedicure Spa. 
4 Do not stand in the whirlpool tub! 
5 This Whirlpool Pedicure Spa has a weight capacity of 250lb. 

 
 

WARNING 

Do Not use if you are diabetic, have poor blood circulation, or if any area of your 

feet or legs are inflamed or have open wounds. Consult a physician before using if 

you have any kind of fungal infection, swelling, fracture, or persistent pain. 

Massage should be pleasant and comfortable. 

IF YOU EXPERIENCE PAIN OR DISCOMFORT, DISCONTINUE USE IMMEDIATELY AND 

CONSULT A PHYSICIAN. 

 
 
This product in whole is in compliance with the applicable                                    

UL LISTED standards and requirements for the US and Canada                            
by Underwriters Laboratories Inc. 
 
 
Some of the components of this product are                                                       
also in compliance with the applicable                                                             

safety standards of the following: 

 

Содержание Petra Collection

Страница 1: ...by spas pedicure COLLECTION OWNER S MANUAL...

Страница 2: ...3 Important Considerations 4 Identifying Parts Description For Petra 700 500 5 Massage System For Petra 450 350R 350V 300 6 Chair Assembly For Petra 700 500 7 Chair Assemb ly For Petra 450 350R 350V...

Страница 3: ...ature is dangerous and should be checked before use Maximum water temperature should not exceed 100 deg F 38 deg C 2 Always enter and exit the Whirlpool Pedicure Spa slowly and carefully 3 Never bring...

Страница 4: ...or following states AZ CA IL MN NE NV OR TX WA and WI All PETRA pedicure spa are equipped with factory installed Dual Check Back Flow Preventer Specification Tested and certified to meet ANSI ASSE sta...

Страница 5: ...ET PUMP IMPELLER 12 OVERFLOW WASTE KNOB 13 POP UP DRAIN STOPPER 14 LIGHT COVER 15 BACK PANEL 16 ARM REST LEVER 17 BASE SHELL 18 WHIRLPOOL JET 19 MASSAGE REMOTE CONTROL 20 SLIDE RECLINE REMOTE CONTROL...

Страница 6: ...T 24V DC 1 2A TRANSFORMER MODEL MKD 57121500 INPUT 120V AC 60Hz OUTPUT 12V DC 1 5A Due to continuous improvements on all our products specifications characteristics packing colors designs are subject...

Страница 7: ...COLD HOT STOP CONTINUE REPEAT THIGHMASSAGE AUTO TAP KNEAD U P DOWN MASSAGEWHEELS J A A B FORWARD BACKWARD UP DOWN 1 2 3 4 8 COLD HOT STOP CONTINUE REPEAT THIGHMASSAGE AUTO T A P KNEAD UP DOWN MASSAGEW...

Страница 8: ...BOLTS 2 ALIGN FOUR BOLTS WITH FOUR HOLES ON THE CHANNEL FRAME 3 TIGHTEN EACH LOCK NUTS TO SECURE THE CHAIR TO THE BASE PETRA 450 PETRA 300 PETRA 350R 350V PETRA Chair Assembly for 450 350R 350V 300 Wa...

Страница 9: ...7L x 28W x 55H 57L x 28W x 48H Capacity All Petra Series 5 gallons Power Source SaniJet 115v 60Hz Whirlpool Pump 0 5HP 115VAC 5 5 Amp 60Hz GFCI protected Plumbing Source Hot Cold Water 0 5 inches Fitt...

Страница 10: ...ure of the day It is extremely important to flush the whirlpool system of the Foot spa to prevent harmful bacteria from growing and to prolong the life of your pedicure spa Remove the Suction Fitting...

Страница 11: ...stic parts Jet casing can be easily cleaned with a non abrasive anti bacterial cleaner when cleaning the tub shell Warning DO NOT use if you are diabetic have poor blood circulation or if any area of...

Страница 12: ...un pump dry 4 Do not relocate pump without prior approval from factory Warning To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times T...

Страница 13: ...ulation or if any area of your feet or leg is inflamed or has open wound s Please consult your physician before using if you have any kind of fungal infection s swelling fracture or persistent pain As...

Страница 14: ...of injury do not permit children to use this product unless they are closely supervised at all times To reduce the risk of electric shock replace damage cord immediately And Do not use extension cord...

Страница 15: ...seconds turn pump off Repeat 10 times If the air is not repleased detach attachment pipe and re attach Quick Tip Use a plunger to release the air lock 2 Pump does not turn on Check the power source C...

Страница 16: ...k main on off power switch check fuse s When massage is not functional Lubrication 1 Turn off the main power 1 Open the screws phillip or Open the zippers from the front of the chair 2 Apply lubricati...

Страница 17: ...ation or maintenance Any applicable warranty shall not apply to J A that have been improper installation or plumbing remanufactured refurbished misused or tampered with in any way LIMITATION OF WARRAN...

Страница 18: ...p replacement too Insert the two tabs of the insert tool into the two notches on the front lens of the light assembly counter clockwise to REMOVE clockwise to INSTALL See figure 1 INSERT TOOL 1 Remove...

Страница 19: ...reproduction of the material contained in the Online Certification Directory subject to the following conditions 1 The Guide Information Designs and or Listings files must be presented in their entire...

Отзывы:

Похожие инструкции для Petra Collection