background image

WARNING!

 

Improperly connecting the grounding wire can result in electrical shock.

Check with a qualified electrician if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the plug provided with tool. Never remove the 

grounding prong from the plug. If the cord or plug is damaged, have it repaired 

before using. If the plug will not fit the outlet, have a proper outlet installed by a 

qualified electrician. The 2x2 must be plugged into an appropriate outlet, properly 

installed and grounded in accordance with all codes and ordinances. The plug 

and outlet should look like those in Figure A.

WARNING!

 

do

 

not

 

use

 

slugger

 

drilling

 

machines

 

on

 

surfaces

 

or

 

materials

 

being

welded

doing

 

so

 

can

 

result

 

in

 

personal

 

injury

 

and

/

or

 

damage

 

to

 

the

slugger

 

drilling

 

machine

.

grounding

 

instructions

6

dRiP LOOP: 

To help prevent cutting fluids from traveling 

along power cord and contacting power source, tie a drip 

loop in power cord as shown in Figure B. 

Fig. B 

Use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole receptacles that accept the tool’s 

plug. Replace or repair damaged cords. Make sure your extension cord is in good condition. When using an extension 

cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop 

in line voltage resulting in loss of power and overheating. Jancy recommends using a minimum 12 gauge extension cord 

not to exceed 100 feet. The table below is supplied only as a guide to minimum gauge for extension cords, where the 

smaller the gauge number, the heavier the cord.

extension

 

cords

minimum

 

gauge

 

for

 

extension

 

cords

 

volts

 

total

 

length

 

of

 

cord

 

in

 

feet

  120V 

0-25 

26-50

  240V 

0-50 

51-100

 

amperage

 

  0-6 

18 

16

  6-10 

18 

16

  10-12 

16 

16

  12-16 

14 

12

recommended

 

wire

 

gauge

*

jancy

 

recommends

 

using

 

a

 

minimum

 12 

gauge

 

extension

 

cord

 

not

 

to

 

exceed

 100 

feet

.

Содержание 17982

Страница 1: ...TECTION REQUIRED Model 17980 120V or 17982 240V Serial Date of Purchase WARNING before use be sure everyone using this machine reads and understands all safety and operating instructions in this manual NEVER PLACE FINGERS NEAR CUTTING AREA OR MACHINE ARBOR LINE VOLTAGE PRESENT BEWARE OF ROTATING MACHINE PARTS ...

Страница 2: ... Inc will within one 1 year from the original date of purchase repair or replace any goods found to be defective in materials or workmanship provided the product warranty registration card has been returned to Jancy Engineering Inc with in thirty 30 days of purchase date This warranty is void if the item has been damaged by acci dent neglect improper service or other causes not arising out of defe...

Страница 3: ...use tools should be stored in a dry high and locked up place out of reach of children 6 Do Not Force Tool It will do the job better and safer at the rate for which it was intended 7 Use Right Tool Do not force a small tool or attachment to do the job of a heavy duty tool Do not use tool for unintended purpose For example Do not use a circular saw for cutting tree limbs or logs 8 Dress Properly Do ...

Страница 4: ...off before connecting to a power source 17 Outdoor Use Extension Cords When tool is used outdoors use only extension cords intended for use outdoors and so marked 18 Stay Alert Watch what you are doing Use common sense Do not operate tool when you are tired Do not use when taking medications that may cause drowsiness 19 Check Damaged Parts Before further use of the tool a guard or other part that ...

Страница 5: ... tooling Keep cutters securely fastened 9 Do not use dull or broken cutters 10 Do not use Slugger drilling machines on surfaces or materials being welded Doing so can damage the machine s electrical components 11 Beware of slugs ejected at end of cut They become HOT during the cut 12 Magnet will not hold properly on thin materials or rough and dirty surfaces 13 Keep bottom of magnet burr free and ...

Страница 6: ...utting fluids from traveling along power cord and contacting power source tie a drip loop in power cord as shown in Figure B Fig B Use only 3 wire extension cords that have 3 prong grounding type plugs and 3 pole receptacles that accept the tool s plug Replace or repair damaged cords Make sure your extension cord is in good condition When using an extension cord be sure to use one heavy enough to ...

Страница 7: ...ft side of frame Replace hub and fastener into frame and tighten securely Install the arbor into the drill motor by inserting the arbor body into the spindle By turning the arbor while inserting the arbor tang will properly line up in the spindle The stop rod item 911 should be between the inducer pin item 904 3 and the hose connection item 904 2 when properly installed Turn the arbor until it bot...

Страница 8: ...lling 1 Move magnet switch to ON position Switch will illuminate to indicate power is present magnetic base should be firmly secured to workpiece at this time Thin materials may require an additional steel plate to achieve proper magnet adhesion 2 Start drill motor by depressing green motor ON button 3 Using the feed handles advance cutter into material until Slugger cutter has established an exte...

Страница 9: ... Valve must turn freely Check coolant lines for blockage Dirt or debris in coolant tank Consistency of coolant mixture too thick Is correct pilot pin being used Vent hole in coolant tank lid blocked 5 Slugs not ejecting from cutter Lack of coolant causing slugs to expand in cutter bore Is correct pilot pin being used Possible broken internal arbor parts 6 Breaking cutters How is coolant being appl...

Страница 10: ...thium base grease 5 Arbor runout should not exceed 0035 inches per revolution This is most accurately measured by placing a dial indicator needle inside of arbor bore and rotating arbor while observing indicator 6 Inspect motor brushes and replace as needed 7 Replace any worn parts and regularly tighten fasteners that have become loose during usage 8 Regularly test machine by placing machine on no...

Страница 11: ...64 1 power cord 220v call 1 703 nut m4 0070133 2 704 washer LOCK m4 06773 6 705 WASher split m4 080720 2 706 FHSCS M4 X 16 07116 1 707 Motor CORD Assembly 07239 1 708 CRPhms m4 x 8 04820 1 709 control panel assy 07206 1 709 1 Panel Plate with label 07207 1 709 2 Circuit board 120V 07294 1 Circuit board 240V 07295 1 709 3 Motor Switch 07208 1 709 4 Magnet Switch 4 Connector BM507 1 709 5 Locking Pi...

Страница 12: ...902 plunger 07530 1 903 spring 07507 1 904 1 coolant inducer 07508 1 904 2 hose connection 07529 1 904 3 inducer pin 07510 1 904 5 seal 07511 2 905 washer 07512 2 906 spacer 07513 1 907 washer 07533 1 908 sss m10 x 10 07336 2 909 retaining ring internal 19w 0215067 1 910 retaining ring external 32z 07215 1 911 stop rod m6 07216 1 912 Rubber washer 07531 1 REV B 1 1 6 0 0 3 3 0 3 1 0 3 7 0 3 6 0 3 ...

Страница 13: ...motor parts 13 REV C ...

Страница 14: ...04544 1 36 bearing needle rhna 101610 07147 1 37 washer thrust 10 1 07148 1 38 gearshaft 12t 07149 1 39 key square 3 x 3 x 36 07161 1 40 gear dual 52t 44t 07150 1 41 retaining ring external 25z 07152 2 42 gear 52t 07162 1 45 pin dowel 4 x 16 07160 1 46 o ring 07153 1 47 cover gear case 07154 1 48 sfhms m4x16 07116 4 49 cover field case 07115 1 50 crphms m4 x 8 04820 4 51 cover cord 07120 1 52 plat...

Страница 15: ...15 wiring diagrams Rev C ...

Страница 16: ...n model max diameter capacity depth usa5 120v 18066 2 3 8 3 usa5 240v 18080 2 3 8 3 jm101 120v 19020 1 3 8 2 jm101 240v 19024 1 3 8 2 jm101 120v with 3 8 slide 19021 1 3 8 2 bar feed handle 2 x 2 120v 17980 2 2 2 x 2 240v 17982 2 2 4 x 4 120v 17985 4 3 4 x 4 240v 17987 4 3 magforce 120v 06920 1 3 8 2 magforce 240v 06921 1 3 8 2 other available slugger drills ...