Item
Setting value /
selectable range
Description
Gamma
0.45, 0.5, 0.55, 0.6, 0.65,
0.75, 0.8, 0.9, 1.0
Select the gamma correction value.
LUTMode
Gamma
Use gamma.
Gamma Function
The gamma function corrects the output signals from the camera beforehand
(reverse correction), taking into consideration the light-emitting properties of the
monitor display. As the light-emitting properties of the monitor are not linear, the
entire image may be darker or the gradation in the dark areas may be less
noticeable when camera outputs are displayed without processing. The gamma
function can be used to correct the camera signals with an opposite-direction curve
and produce a display that is close to linear.
0
0.2
0.4
0.6
0.8
1.0
1.2
Example of the light-emitting
properties of the monitor display
X
Y
Input ->
<
-
O
utp
ut
■
To use the gamma function
Configure the settings as follows.
Note
You can use the LUT function to configure a curve with more detailed points. For
details, see “Lookup Table (LUT)”.
SW-8000T-10GE/SW-8000T-SFP
— 33 —
Содержание SW-8000T-10GE
Страница 8: ...Parts Identification SW 8000T 10GE SW 8000T SFP 8 SW 8000T 10GE SW 8000T SFP ...
Страница 63: ...Spectral Response SW 8000T 10GE SW 8000T SFP 63 Wave length nm Relative Response ...
Страница 64: ...Dimensions F mount SW 8000T 10GE F Dimensional tolerance 0 3mm Unit mm SW 8000T 10GE SW 8000T SFP 64 ...
Страница 65: ...M52 mount SW 8000T 10GE M52 Dimensional tolerance 0 3mm Unit mm SW 8000T 10GE SW 8000T SFP 65 ...
Страница 66: ...F mount SW 8000T SFP F SW 8000T 10GE SW 8000T SFP Dimensional tolerance 0 3mm Unit mm 66 ...
Страница 67: ...M52 mount SW 8000T SFP M52 SW 8000T 10GE SW 8000T SFP Dimensional tolerance 0 3mm Unit mm 67 ...