Setting range
Default value
Description
Configure pulse generator settings.
1〜4096
5.4
Set the division value for the prescaler (12 bit) using PixelClock as the base
clock.
0.0181274〜74.25
0.6
Set the clock used for the pulse generator.
This value is calculated using the [ClockPreScaler] value as a base.
0: PulseGenerator0,
1: PulseGenerator1,
2: PulseGenerator2,
3: PulseGenerator3
PulseGenerator0
Select the pulse generator.
[setting range]
0: PulseGenerator0, 1: PulseGenerator1, 2: PulseGenerator2, 3: PulseGenerator3
PulseGeneratorLength
1〜1048575
30000
Set the maximum count-up value as a clock count.
PulseGeneratorLengthMs
1 / PulseGeneratorClock (MHz)
〜1048575 /
PulseGeneratorClock (MHz)
50
Set the maximum count-up value in milliseconds.
This value is calculated using the [PulseGeneratorLength] value as a base.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorFrequency
PulseGeneratorClock (MHz) ÷
1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
20
Set the maximum count-up value as a frequency.
This value is calculated using the [PulseGeneratorLength] value as a base.
PulseGeneratorStartPoint
0 〜 1048574
0
Set the start point of the High interval as a clock count. When the counter
reaches this value, the output will be 1.
PulseGeneratorStartPointMs
0 〜 1048575 /
PulseGeneratorClock (MHz)
0
Set the start point of the High interval in milliseconds.
When the counter reaches this value, the output will be 1.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorEndPoint
1 〜 1048575
15000
Set the start point of the Low interval as a clock count. When the counter
reaches this value, the output will be 0.
PulseGeneratorEndPointMs
1/ PulseGeneratorClock (MHz)
〜
1048575 /
PulseGeneratorClock (MHz)
25
Set the start point of the Low interval in milliseconds.
When the counter reaches this value, the output will be 0.
The setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorPulseWidth
ー
25
Display the High interval width of the pulse in milliseconds.
The duration between the Start Point and End Point is calculated. The
setting range varies depending on the [ClockPreScaler] value.
PulseGeneratorRepeatCount
0 〜 255
0
Set the repeat count for the counter.
When this is set to [0], a free counter is enabled with no repeat limit.
PulseGeneratorClearActivation
0: Off,
1: RisingEdge,
2: FallingEdge,
3: LevelHigh,
4: LevelLow
Off
Set the clear signal condition for the count clear input of the pulse
generator.
[setting range]
0: Off, 1: RisingEdge, 2: FallingEdge, 3: LevelHigh, 4: LevelLow
PulseGeneratorClearSource
ー
ー
Set the clear signal condition for the count clear input of the pulse
generator.
[setting range]
refer to "Pulse Generator".
PulseGeneratorClearSyncMode
0:AsyncMode,
1:SyncMode
AsyncMode
Select the sync mode for the count clear input signal.
PulseGeneratorSelector
PulseGeneratorClock (MHz)
ClockPreScaler
m) PulseGenerator
Item
SP-45001M-CXP2A/SP-45001C-CXP2A
- 63 -