Next trigger disabled
Next trigger
Input enabled
B
Exposure time
Trigger
Sensor
Exposure
Exposure
Active
Readout
■ When [ExposureMode] is [Timed]
• FrameStartTrigger On
A (Frame Period)
Timing chart
Acquisition
Control
SP-45000M-CXP4A/SP-45000C-CXP4A
PixelFormat
Frame Period [A] (usec)
Period From Trigger start edge to
Exposure start [B] (usec)
Mono8
19231
37.4
Mono10
22884
37.4
Mono12
27473
37.4
BayerRG8
19231
37.4
BayerRG10
22884
37.4
BayerRG12
27473
37.4
Mono8
19321
37.4
Mono10
22884
37.4
Mono12
27473
37.4
Vertical Binning On
Mono8
19231
37.4
Mono10
22884
37.4
Mono12
27473
37.4
Mono8
19231
37.4
Mono10
22884
37.4
Mono12
27473
37.4
Binning Off
Horizontal Binning On
Horizontal Binning On & Vertical Binning On
CXP12-4