— 44 —
GO-5101M-PGE / GO-5101C-PGE
■
Internal camera blocks
Frametrigger
Event
detection
Counter
At event occurrence or count up
Counter
Counter
Counter
Counter reset
Internal MCU of camera
Read requested
counter value
Send
information
via GVCP
Event
detection
Event
detection
Event
detection
Exposure Start
Frame Start
FrameTransfer End
■
To use the counter function
Configure the settings as follows.
Three counters can be configured (Counter 0 to 2).
Item
Setting value / selectable range
Description
Counter 0 to 2
Counter 0 to 2
Select the counter.
Counter 0 to 2 Event Source
Off,
Frame Trigger,
Frame Start,
Exposure Start,
Frame Transfer End
Select the counter event signal for
which to read the count value.
Counter 0 to 2 Event Activation
Rising Edge (fixed)
or Falling Edge
Specify the timing at which to count.
Note
The four counter event signals are always counted up internally on the camera.
Counter and Timer Control Function (counter support only)
The counter function counts up change points in the camera’s internal signals using the camera’s
internal counter, and reads that information from the host side. This function is useful for verifying error
conditions via the count value using internal camera operations.
Counting is performed at frame trigger, frame start, exposure start, and exposure transfer end, and
by comparing these values, you can determine the internal camera state at which missed triggers will
occur.
■
Counter occurrence diagram
Frame trigger
Frame trigger counter
Set to count 1
Exposure Start
Exposure start counter
Set to count 2
GVCP transmission
GVCP reception
Event occurrence
Event occurrence
Count up
Count up
Count 2
request
Read count
value
Count 1
Request
Read count
value
Counter reset
Counter reset
Count 1 reset
Count 2 reset
Note