GO-5100MC-PGE | GO-5101MC-PGE | User Manual (Ver. 2.0)
Main Functions
- 50 -
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
Scanning Range
Shortest Period
8 bit
10 bit
12 bit
Full
44.1 ms
66.1 ms
88.1 ms
ROI 2/3 (Height=1370)
29.4 ms
44.1 ms
58.7 ms
ROI 1/2 (Height=1028)
22.0 ms
33.1 ms
44.1 ms
ROI 1/4 (Height=514)
11.0 ms
16.6 ms
22.1 ms
ROI 1/8 (Height=257)
5.52 ms
8.27 ms
11.0 ms
Binning Vertical 2 (Monochrome models only)
22.0 ms
33.1 ms
44.1 ms
The shortest periods of trigger in the table above are values for when the trigger overlap is set to
“Readout.” When the trigger overlap is set to “Off,” the exposure time will be added to the periods.
When Exposure Mode is Timed
Example: When Trigger Source is set to Line 5 - Optical In 1 and OptIn Filter Selector is set to
10 μs
l
Trigger Overlap: OFF
t1
t2
t3 (Min)
8 bit
10 μs (Min)
40 μs
28 ms
10 bit Packed
79 μs
55 ms
10 bit
Note:
If the exposure time is longer than (input trigger cycle - t3), the next trigger input will not be