User Manual (Ver. 2.0) - Short ASCII Command List
GO-5000M-PMCL | GO-5000M-PMCL-EP | GO-5000M-PMCL-UV
- 108 -
Digital IO Control
Related Topic:
Name
Access Short ASCII
Values
MIN MAX Default
Description
LineInverter_Nand0In1 R/W
ND0INV1
False/True
0
1
0
ND0INV1=[Param.]<CR><LF>
ND0INV1?<CR><LF>
LineInverter_Nand0In2 R/W
ND0INV2
False/True
0
1
0
ND0INV2=[Param.]<CR><LF>
ND0INV2?<CR><LF>
LineInverter_Nand1In1 R/W
ND1INV1
False/True
0
1
0
ND1INV1=[Param.]<CR><LF>
ND0INV1?<CR><LF>
LineInverter_Nand1In2 R/W
ND1INV2
False/True
0
1
0
ND1INV2=[Param.]<CR><LF>
ND0INV2?<CR><LF>
LineSource_Line1
R/W
LS0
0: Low
1: High
3: Frame
TriggerWait
4: Frame Active
5: Exposure
Active
6: Fval
7: Lval
8: Pulse
Generator0
13: CL_CC1_In
14: Nand0
15: Nand1
0
15
0
LS0=[Param.]<CR><LF>
LS0?<CR><LF>
For 12pin TTL out
LineSource_Nand0In1
R/W
ND0IN1
Same as for Line1 0
15
0
ND0IN1=[Param.]<CR><LF>
ND0IN1?<CR><LF>
LineSource_Nand0In2
R/W
ND0IN2
Same as for Line1 0
15
0
ND0IN2=[Param.]<CR><LF>
ND0IN2?<CR><LF>
LineSource_Nand1In1
R/W
ND1IN1
Same as for Line1 0
15
0
ND1IN1=[Param.]<CR><LF>
ND1IN1?<CR><LF>
LineSource_Nand1In2
R/W
ND1IN2
Same as for Line1 0
15
0
ND1IN2=[Param.]<CR><LF>
ND1IN2?<CR><LF>