EL-2800M-USB / EL-2800C-USB
- 42 -
7.3.3 Trigger Overlap
This function defines whether or not a trigger pulse can be accepted while data is being read out.
OFF
:
The trigger pulse is not accepted during CCD readout.
Read Out
:
The trigger pulse can be accepted during CCD readout
7.4. Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)
This is used for applications which do not require triggering. In this mode, the video signal for the
auto-iris lens is available.
Primary settings to use this mode
Trigger control
Trigger Mode: OFF
Table - 20 Minimum interval of the image (8-bit)
Readout mode
FULL
2/3 AOI
1/2 AOI
1/4 AOI
1/8 AOI
1/2V
Binning
(Note1)
Minimum frame lines
745
565
475
340
273
376
Note 1) Only for EL-2800M-USB
7.5. Timed mode (EPS)
This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the
exposure period.
Primary settings to use this mode
Exposure mode: Timed
Trigger mode: ON
Frame Start: ON
Table - 21 Minimum interval of the trigger pulse (Sensor Tap Geometry: 1X2 – 2YE)
Readout mode
FULL
2/3 AOI 1/2 AOI 1/4 AOI 1/8 AOI
1/2V
Binning
(Note1)
Minimum
interval
lines
746
566
476
341
274
377
Note 1) EL-2800M only
Note 2) This table shows in case of Trigger overlap being set to Readout. If Trigger
overlap is set to OFF, this period is longer than the figures in this table.