CV-M9 CL
7. Configuring the Camera
7.1. Setting by internal Switch SW301
SW 301 is used for communication port select and trigger termination. The switch is placed on
the rear board behind the LED and WB button.
To access the switch:
Remove the top cover frame. 6 screws.
Remove the bottom cover frame. 6 screws.
Remove left side cover. (Seen from rear). 5 screws.
SW 301 is seen on the rear board behind the LED and WB button.
No
Functions
OFF
ON
1 Communication port switch
LVDS (Camera Link)
RS232C (HIROSE 12pin)
2 Trigger In Termination switch
TTL
75
Ω
Factory settings are shown in
Bold Italic
.
Fig. 34. Switch position
- 29 -